DISPLAY
The CDG Series dispensers have multiple display options available. Reference the applicable
display option(s) for your dispenser.
LCD
ALWAYS FRESH
ALWAYS FRESH 35 F
ALWAYS FRESH *
ALWAYS FRESH DEF
LED INDICATOR
Always allow the dispenser to run empty for one hour to achieve proper operating temperature.
Compartment temperature during normal operation should be 32°F to 41°F (0°C to 5°C).
CONFIRMS POWER
LCD turns ON by switching the power control switch ON.
"ALWAYS FRESH" = Power is ON.
o
No display = Power is OFF.
o
INFORMATION DISPLAYED
LCD indicates the compartment temperature.
"ALWAYS FRESH" + flash compartment temperature.
o
LCD indicates the compressor cycle.
Asterisk "*" identifies compressor cycle in progress.
o
"ALWAYS FRESH" + alternately flashing asterisk and
o
compartment temperature.
LCD indicates the automatic defrost cycle or service.
"ALWAYS FRESH DEF" = Automatic defrost in progress.
o
"ALWAYS FRESH ERR" = Service is required.
o
Contact KanPak Equipment Service when unit requires servicing.
CONFIRMS POWER
POWER LED turns ON by switching the power control switch ON.
Solid Green = Power is ON.
o
No light = Power is OFF.
o
INFORMATION DISPLAYED
READY LED indicates the compartment temperature.
Solid Green = Temperature is 32°F to 41°F
o
Flashing Green = Temperature is 42°F to 46°F
o
No Light = Temperature is not 32°F to 46°F
o
automatic defrost cycle in progress.
DEFROST LED indicates the automatic defrost cycle or service.
Solid Yellow = Automatic defrost in progress.
o
Flashing Yellow = Service is required.
o
No Light = Defrost is not in progress.
o
Contact KanPak Equipment Service when unit requires servicing.
Page 7
(0°C to 5°C).
(5.6°C to 7.8°C).
or