E. Install the Junction Box
•
Remove the junction box assembly from the valve
compartment.
•
If the box is being wired from the OUTSIDE of the
appliance:
-
Loosen two screws on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screws.
-
Make all necessary wire connections to the receptacle,
assemble the receptacle and cover to the junction
box.
-
Attach the junction box assembly to the outside of the
appliance with the two screws provided.
•
If the box is being wired from the INSIDE of the
appliance:
-
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
-
Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
-
Make all necessary wire connections to the receptacle,
assemble the receptacle and cover to the junction
box.
-
Attach the junction box assembly to the inside of the
appliance with the two screws provided.
•
If the box is not to be wired at the time of appliance
installation, assemble the receptacle and cover to the box
and install on the inside of the appliance.
Heatilator • Caliber Multi-Sided B-Vent • 4002-094 Rev H • 11/07
WARNING
Shock Risk
Explosion Risk
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch
•
Incorrect wiring will damage millivolt
values.
•
Incorrect wiring will override IPI safety
lockout and may cause explosion.
14-2 with ground Romex is the recommended
wiring to the appliance junction box.
14-2 with
Ground Romex
WHITE
Figure 10.4 Junction Box Detail
BLACK
GROUND
23