Installation; Technical Specifications - Lincoln Electric TOMAHAWK 375 AIR Operator's Manual

Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS -TOMAHAWK™ 375 AIR
Duty Cycle
100%
60%
35%
Current
Range
10-25 Amps
REQUIRED GAS FLOW RATE
70 PSI @ 125-200 SCFH
( 5 Bar. @ 80±20 LITERS/MIN.)
RECOMMEND INPUT WIRE AND FUSE SIZES
Output
AC Input
Input Cord Plug Size
Voltage
at
60 Hertz
230V-1Ø
25 A
208V-1Ø
Height
15.2 in.
385 mm
OPERATING TEMPERATURE RANGE
-10°C to +40°C

INSTALLATION

INPUT - SINGLE PHASE 60 HERTZ
Standard Voltage
208V, 230V ±10% / 1 / 60Hz
RATED OUTPUT AT 40° C
CURRENT AMPS
OUTPUT
Open Circuit
Voltage
460 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
(Super Lag)
Circuit Breaker
(Delay Type)
6-50P
PHYSICAL DIMENSIONS
Width
8.5 in.
215 mm
TEMPERATURE RANGES
TOMAHAWK™ 375 AIR
13 A
18 A
25 A
REQUIRED GAS INLET PRESSURE
80 to 110 PSI
(6 Bar. to 7.5 Bar.)
o
C or Less
Fuse
Type S, SO, ST, STO or extra
hard usage input cord
2 Input Supply Wires 1 Ground Wire
20 AMPS
#12 (3.3 mm
Depth
18.9 in.
480 mm
STORAGE TEMPERATURE RANGE
-10°C to +40°C
VOLTAGE VOLTS
85.2 VDC
87.2 VDC
90 VDC
Pilot Current
12 Amps
AWG (IEC) Sizes
2
)
#12 (3.3 mm
Weight
Including
Torch Cable
40 - 40.8 lbs.
18-18.5 kg.
A-1