Advertisement

Quick Links

ELAR PAR 72 UV
Elation Professional™
6122 S. Eastern Ave.
Los Angeles, Ca 90040
www.elationlighting.com
Rev. 12/08/2010 – visage
Version 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Elation ELAR PAR 72 UV

  • Page 1 ELAR PAR 72 UV Elation Professional™ 6122 S. Eastern Ave. Los Angeles, Ca 90040 www.elationlighting.com Rev. 12/08/2010 – visage Version 1.0...
  • Page 2 ELAR PAR 72 UV ™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 3: Table Of Contents

    ELAR PAR 72 UV ™ TABLE OF CONTENS General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 4 Safety Instructions………………………………………………………..…………. 5 Features……………………………………………………………………………………7 General Guidelines………………………………………………………………………. 8 Fixture Overview…………………………………………………………………………. 9 Mounting and Installation………………………………………………………….……. 12 Understanding DMX……………………………………………………………………... 15 a.
  • Page 4: General Information

    INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The ELAR PAR 72 UV™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
  • Page 5: Warranty Registration

    Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The ELAR PAR 72 UV™ carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number.
  • Page 6: Safety Instructions

    4. For safe operation, follow the Installation guide described in chapter six of this manual. Operating the ELAR PAR 72 UV™ without suited safety aids such as safety cables or clamps can increase the risk of damage and/or personal injury.
  • Page 7 ELAR PAR 72 UV ™ 12. Always disconnect from main power before performing any type of service or any cleaning procedure. 13. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord.
  • Page 8: Features

    Sound-controlled via built-in microphone • DMX Modes: 2 DMX channels • DMX-control via standard DMX-controller • Upgradable firmware via Elation “E-Loader” Data Pack • Electronic Switching Power Supply 100v~240v • Flicker-free operation for television and film • Compact design: fits in 12” box truss •...
  • Page 9: General Guidelines

    ELAR PAR 72 UV ™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so.
  • Page 10: Fixture Overview

    ELAR PAR 72 UV ™ 5. FIXTURE OVERVIEW ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 11 UV™. Please do not daisy chain power for more than 16 fixtures. To maintain the integrity of the IP rating, only use proper Elation IP rated power cables. 4. DMX Out Lead – This lead is used to send an incoming DMX signal to the next fixture in the DMX chain.
  • Page 12 ™ cable that converts a standard Edison 3-prong to the IP rated twist lock connector. When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating. 11. DMX In Lead – This lead is the main DMX input lead. When the unit is the first in a...
  • Page 13: Mounting And Installation

    ELAR PAR 72 UV ™ 6. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were unauthorized personnel might reach the fixture. Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
  • Page 14 See the image below. Clamp Mounting The ELAR PAR 72 UV™ provides a unique mounting bracket assembly that allows the unit to stand on a flat surface or to be hung on truss via a clamp in any safe position (see the illustration above).
  • Page 15 See illustrations below. Securing the ELAR PAR 72 UV™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means. The fixture provides a built-in rigging point for a safety cable as illustrated above.
  • Page 16: Understanding Dmx

    1 to that fixture no matter where it is located in the DMX chain. The ELAR PAR 72 UV™ can be controlled via DMX-512 protocol. The ELAR PAR 72 UV™ is a fixture that operates with two DMX channels (see pages 29 &...
  • Page 17: Dmx Terminator

    2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line. Using a line terminator (Elation part: DMX T PACK) will decrease the possibilities of erratic behavior.
  • Page 18: 3-Pin To 5-Pin Conversion

    ELAR PAR 72 UV ™ 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores.
  • Page 19 That means changing the settings of one channel will only affect the selected fixture. In the case of the ELAR PAR 72 UV™, which is up to a two channel fixture, you should set the starting DMX address of the first unit to 1, the second unit to 3 (2 + 1), the third unit to 5 (2 + 3), and so on.
  • Page 20: Display Indicators

    ™ 8. DISPLAY LED INDICATOR. The ELAR PAR 72 UV ™ has a LED indicator on the display. This indicator is designed to give a quick visual indication of the fixtures’ DMX status. The illustration below details the functionality of the LED indicators.
  • Page 21: Display Menu

    ELAR PAR 72 UV ™ 9. DISPLAY MENU Default settings shaded. VALU A001~AXXX (AXXX) DMX address setting <ADDR> SLAV ON/OFF Set as Slave RDMX ON/OFF Change address via DMX <RUN> AUTO ALON/MAST Run Auto program VALU D-XX D-00(DXXX) Display DMX value...
  • Page 22 ELAR PAR 72 UV ™ DMX addressing also allows the fixture to ignore any DMX information coming from the controller that is not meant specifically for the fixture. Because each fixture is connected in a daisy-chain fashion it is imperative to assign a proper and unique starting DMX address to each and every fixture.
  • Page 23 ELAR PAR 72 UV ™ 9.1.3 <DISP> - Menu Display Settings This function allows the internal programs to run in either stand-alone or master/salve DMX chain. In “Alone” mode “VALU” - Display the DMX 512 value of each channel This function will electronically display the current DMX value for any channel that is currently being adjusted.
  • Page 24 ELAR PAR 72 UV ™ <FAIL> DMX Fault Protection This function dictates how the fixture will operate in the event DMX signal is suddenly lost while operating in DMX mode. The three fail safe modes are; 1) “OFF” which will blackout all light output.
  • Page 25 ELAR PAR 72 UV ™ <CODE> Clear run time access code This lock-out code prevents the current run time from being erased accidently. The access code is “038” <CLFE> Clear Fixture Run Time This function resets the run time to zero.
  • Page 26 ELAR PAR 72 UV ™ displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX value is “XX.” 6. Adjust the DMX value by tapping the UP button, until you get the expected effect for this channel.
  • Page 27 ELAR PAR 72 UV ™ Adjust the Step-time as described above. 10. Call up the second scene in your controller now. 11. Repeat steps 5-11 until all desired scenes are downloaded. 12. Press MODE/ESC to exit. The number of steps can be defined under “STEP”...
  • Page 28: Dmx Addressing

    ELAR PAR 72 UV ™ 10. DMX ADDRESSING Setting the DMX address - After the fixture is turned “ON” it will immediately complete a reset process that test all the fixture’s functions. When the reset process concludes the LCD will display the fixture’s current DMX address. If the fixture is not receiving a DMX signal, the display will flash continuously.
  • Page 29 ELAR PAR 72 UV ™ 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings: 1. Set the DMX value of channel 1 to a value of 7. 2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"...
  • Page 30: Dmx Traits

    ELAR PAR 72 UV ™ 11. DMX TRAITS DMX Operation Notes: The fixture will function in DMX mode whenever the unit is receiving a DMX signal. Please note that this will override all manual settings. This unit will keep and retain the last DMX command in the event of DMX signal failure. To reset the fixture you must turn the power off.
  • Page 31 ELAR PAR 72 UV ™ The chart below and on the preceding pages outlines the different DMX traits for the two different DMX modes. DMX channel functions values (2 DMX channels): Channel Value Function Shutter, strobe: 0-31 Blackout (LEDs Off)
  • Page 32: Working With Built-In Programs

    ELAR PAR 72 UV ™ 12. WORKING WITH BUILT-IN PROGRAMS The fixture comes equipped with a built-in DMX recorder that allows custom programs to be installed and recalled directly from the fixture’s control board. Programs can be created and stored using the fixture’s control board or by using an external DMX controller. The following instructions will detail the procedures for using the on-board system menu as well as using a DMX compliant controller.
  • Page 33 ELAR PAR 72 UV ™ Step 2 – Building Scenes. The fixture will store a maximum of 48 scenes. These scenes are then used to create the programs. A program can store one or a maximum of 48 steps. To create a scene for playback follow the procedure below;...
  • Page 34 ELAR PAR 72 UV ™ • Access the main menu and use the “Up” and “Down” to toggle to “Mode” and tap the “Enter” button. • In the next screen select “Run” and tap Enter. • In the next screen toggle to “Auto” and tap enter. There are now two selections, “Master”...
  • Page 35: Lens Replacement

    ™ 13. LENS REPLACEMENT The ELAR PAR 72 UV comes with a removable front cover that allows the lens assembly to be changed out to achieve different beam angles. Lens cover is held in place by two ¼ turn locking fasteners. To remove the cover; 1) Turn the locking fasteners in a counter-clockwise direction.
  • Page 36: Cleaning And Maintenance

    ELAR PAR 72 UV ™ 14. CLEANING AND MAINTENANCE Consider the following points during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.
  • Page 37: Warranty

    ® defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement ®...
  • Page 38 ® liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional Products ® and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
  • Page 39: Photometric Data

    ELAR PAR 72 UV ™ PHOTOMETRIC DATA ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 40: Dimensional Drawings

    ELAR PAR 72 UV ™ DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 41: Circuit Schematic

    ELAR PAR 72 UV ™ CIRCUIT SCHEMATIC ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 42: Technical Specifications

    ELAR PAR 72 UV ™ TECHNICAL SPECIFICATIONS Power supply: AC 100v-240v~ , 50Hz / 60Hz Power consumption: Maximum 80w LED Configuration: 36 x 2 Watt UV LEDs IP Rating: IP65 Weight: 6 Kgs / 15.2Lbs DMX Channels: 2 Channels DMX Drive: Standard DMX-512, 3 pole IP Rated Locking Connector;...
  • Page 43 ELAR PAR 72 UV ™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 44 Elation Professional 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighting.com Rev. 12/08/2010 – visage Version 1.0...

Table of Contents