Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• Depending on the model, your server might look different from the illustrations in this topic.
• Use any documentation that comes with the hot-swap storage drive and follow those instructions in
addition to the instructions in this topic.
To install or replace a hot-swap storage drive, do the following:
1. Read the following storage drive installation rules:
• Follow the order of the storage drive bays when installing a storage drive. See "Front view of the
server" on page 17 to locate the storage drive bays in your server.
• For RAID configuration, the storage drives must be the same type with the same capacity if they are
within a single RAID array. For more information, see "Configuring RAID" on page 58.
• For storage drives with different capacities, install the storage drive by following the order of the
storage drive bays as well as the order from the lowest capacity to the highest capacity.
2. Open the front door (if available).
3. Locate the appropriate storage-drive bay. See "Front view of the server" on page 17.
4. Press the release button
Figure 69. Opening the handle of the hot-swap storage drive or the dummy tray
1
to open the handle of the hot-swap storage drive or the dummy tray.
.
Chapter 6