To install the flash module, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the Rack Installation Instructions that comes with the server. If
the server is in tower form factor, lay the server on its side for easier operation.
3. Remove the server cover. See "Removing the server cover" on page 66.
4. Locate the AnyRAID adapter. See "Server components" on page 25.
5. Remove any parts and disconnect any cables that might impede your operation.
6. Position the flash module above the AnyRAID adapter and align the two holes in the flash module with the
two pins on the AnyRAID adapter. Then, lower the flash module straight down until it is securely seated.
Note: If necessary, remove the AnyRAID adapter first for easier operation. See "Replacing the AnyRAID
adapter or the pass-through board" on page 143.
Figure 57. Installing the flash module
7. Reinstall any parts and reconnect any cables that you have removed.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation, go to "Completing the parts replacement" on page 164.
Removing the flash module
Attention: Do not open your server or attempt any repair before reading and understanding "Safety information"
on page iii and "Guidelines" on page 63.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note: Depending on the specific type, your AnyRAID adapter and the flash module might look different
from the illustration in this topic.
If the AnyRAID adapter in your server has a flash module installed, do the following when you want to
remove the flash module:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.