Troubleshooting - Porter-Cable C6001 Instruction Manual

Porter-cable air compressor maintenance-free pump
Hide thumbs Also See for C6001:
Table of Contents

Advertisement

Available languages

Available languages

You can also write to us for information at PORTER-CABLE, 4825 Highway 45
North, Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include
all of the information shown on the nameplate of your tool (model number, type,
serial number, etc.).
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to voltage sources, com-
pressed air, or moving parts. Before servicing unit unplug or disconnect
electrical supply to the air compressor, bleed tank of pressure, and allow the
air compressor to cool.
PROBLEM
Excessive tank pressure
- safety valve pops off.
Air leaks at fittings.
Air leaks in air tank or at
air tank welds.
Air leaks between head
and valve plate.
Air
leak
from
valve.
Knocking Noise.

TROUBLESHOOTING

CAUSE
Pressure switch does
not shut off motor when
compressor reaches
"cut-out" pressure.
Pressure switch "cut-
out" too high.
Tube fittings are not
tight enough.
Defective air tank.
Leaking seal.
safety
Possible defect in
safety valve.
Possible defect in
safety valve.
17 - ENG
CORRECTION
Move On/Off lever to
the Off position, if the
outfit does not shut
off contact a Trained
Service Technician.
Contact a Trained
Service Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with
soapy water solution.
Do Not Overtighten.
Air tank must be
replaced. Do not repair
the leak.
Risk
bursting. Do not drill
into, weld or otherwise
modify air tank or it will
weaken. The tank can
rupture or explode.
Contact a Trained
Service Technician.
Operate safety valve
manually by pulling on
ring. If valve still leaks,
it should be replaced.
Operate safety valve
manually by pulling on
ring. If valve still leaks,
it should be replaced.
1000002853

Advertisement

Table of Contents
loading

Table of Contents