TYPICAL INSTALLATION
POWER AND GROUND WIRING CONNECTIONS
3
Attach power and ground wires to terminals.
Line Power 115 Vac Single Phase

INSTALL 3-BUTTON CONTROL STATION

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing door
control.
To prevent possible SERIOUS INJURY or DEATH from a closing
door:
• Install door control within sight of door, out of reach of
children at a minimum height of 5 feet (1.5 m) and away from
ALL moving parts of door.
• Install the control station far enough from the door to prevent
the user from coming in contact with the door while operating
the controls.
1
Remove the control station cover.
2
Fasten the control station to the wall at least 5 feet above the
ground. The installation surface must be smooth and fl at.
5'
(1.5 m)
Ground
AVERTISSEMENT
AVERTISSEMENT
^
O P
E N
Screws
O
S T
O P
Wall
3-Button Control
ADVERTENCIA
Station
Power
WARNING
WARNING
WARNING
• Install the entrapment warning placard on wall next to the
control station in a prominent location that is visible from the
door.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep door in sight until completely closed. NEVER
permit anyone to cross path of closing door.
3
Select appropriate knockout and run the wires to the operator.
ADVERTENCIA
12
Control
Conduit
^
O PE
N
O
ST
OP
^
O P
E N
Knockout
O
S T
O P

Hide quick links: