Exmark Lazer Z CT Operator's Manual page 27

Hide thumbs Also See for Lazer Z CT:
Table of Contents

Advertisement

For Exmark Mower Parts Call 606-678-9623 or 606-561-4983
4.1.2
4.1.3
4.1.4
Clean engine air cooling system:
Service Interval: Daily or more often in dry conditions
POTENTIAL HAZARD
♦ Excessive debris can cause the engine
and hydraulic system to overheat.
WHAT CAN HAPPEN
♦ Excessive debris around the engine
cooling air intake and inside of the pump
compartment can create a fire hazard.
HOW TO AVOID THE HAZARD
♦ Clean all debris from around the engine
and hydraulic pumps daily.
a)
Stop engine, wait for all moving parts to stop, and remove key. Engage
parking brake.
b)
Clean all debris from rotating engine air intake screen and from around
engine shrouding.
Check battery charge:
Service Interval: Monthly
Allowing batteries to stand for an extended period without recharging them will
result in reduced performance and service life. To preserve optimum battery
performance and life, recharge batteries in storage when the open circuit voltage
drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged before
putting away for winter storage.
a) Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6 volts
or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below for
recommended charger settings).
Voltage
Percent
Reading
Charge
12.6 or greater
100%
12.4 – 12.6
75 – 100%
12.2 – 12.4
50 – 75%
12.0 – 12.2
25 – 50%
11.7 – 12.0
0 – 25%
11.7 or less
0%
Clean grass build-up under deck.
Service Interval: Daily
a)
Stop engine, wait for all moving parts to stop, and remove key. Engage
parking brake.
www.mymowerparts.com
CAUTION
Maximum
Charger Settings
16 volts/7 amps
16 volts/7 amps
16 volts/7 amps
14.4 volts/4 amps
14.4 volts/4 amps
14.4 volts/2 amps
22
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links: