Installation Of Wired Controller And Project Debugging; Installation Of Wired Controller - Fisher FSL-1100B-H-3F Operation Manual

The ducted split type air-conditioning units
Table of Contents

Advertisement

4、Installation of Wired Controller and Project Debugging

4.1 Installation of Wired Controller

No.
Description
Socket's base
box installed in
the wall
Fig.4.1: Sketch for Installation of Wired Controller. Pay attention to the following items during
installation of wired controller:
1. Cut off power supply of heavy-current wire embedded in mounting hole in the wall before
installation. It is prohibited to perform the whole procedure with electricity.
2. Pull out 4-core twisted pair line in mounting hole and then make it through the rectangle hole at
the back of controller's soleplate.
3. Joint the controller's soleplate on wall face and then fix it in mounting hole with screws M4X25.
4. Insert the 4-core twisted pair through rectangle hole into controller's slot and buckle the front
panel and soleplate of controller together.
5. At last, fix the controller's front panel and soleplate with screws ST2.2X6.5.
Caution:
During connection of wirings, pay special attention to the following items to avoid interference of
electromagnetism to unit and even failure of it.
1. To ensure normal communication of the unit, signal line and wiring (communication) of wired
controller should separate from power cord and indoor/outdoor connection lines. The distance between
Fig.4.1: Sketch for Installation of Wired Controller
1
2
Soleplate of
controller
3
Screw M4X25
7
4
Front panel of
Screw
controller
ST2.2X6.5
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsol-1100b-3f

Table of Contents