Raised Hearth Extension And Raised Fireplace - Heatilator I60 Installation Manual

Table of Contents

Advertisement

2. Raised Hearth Extension and Raised Fire-
place
Non-combustible flooring a minimum of 20 in. (508 mm)
in front of and 12 in. (305 mm) to each side of the fuel
opening is required.
The hearth framing must be constructed of non-com-
bustible materials (such as metal framing or equivalent
material) and placed on HX3(s), HX4(s), or equivalent
material. See Figure 7.8.
When creating the platform, allow for the thickness
of the non-combustible finishing materials.
Seal gaps between the hearth extension and the front
of the fireplace with a bead of non-combustible sealant
or grout.
20 in. minimum
Hearth Extension
1/2 in. Micore
or equivalent
insulation
Figure 7.8
Raised Hearth Extension and Fireplace Framing Materials
Continuous,
non-combustible sealant
Tile, stone or other
non-combustible finishing
material
Protective Metal
Hearth Strips
Non-combustible
Framing Material
Heatilator • I60/I80 • 4013-260 Installers Manual • Rev G • 10/07/13
Note: The bottom of the fireplace
opening is 7-5/8 in. (194 mm)
above the bottom of the
fireplace. Finished hearth must
NOT extend above this level.
Platform must be built
to raise the bottom of
the fireplace opening
to the level of the
desired hearth height.
Floor and platform constructed of
wood or other combustible material
31