TROUBLESHOOTING GUIDE (continued)
ADDITIONAL PROBLEMS
Symptom
Possible Cause
Warped or damaged
Excessive
blower fan.
vibration
Loose bolt or fastener.
Internal engine damage.
Damaged A-V cushions.
Blower intake or
Engine
discharge ports or tubes
overspeeding
are clogged with debris.
Impeller blades are
missing or damaged.
20
Remedy
Consult your servicing
dealer.
Tighten as required.
Consult your servicing
dealer.
Replace cushions.
Remove debris.
Consult your servicing
dealer.
ASSEMBLING THE BLOWER (continued)
115mm
Clamp
48002A
90 ° Discharge Tube
100mm Clamp
90 ° Discharge Tube
Handgrip
Flexible Tube
6. Grasp the straight tube as shown,
and push the tube over the swivel
tube locking pins (right).
7. Lock the straight tube to the swivel
tube by rotating the straight tube.
8. Grasp the nozzle tube and lock the
nozzle to the straight tube as in
Steps 6 and 7.
IMPORTANT!
Blower tube installation affects blower
balance and performance! Make sure
the tubes and nozzle are correctly
assembled per above, and that all
connections are tight.
WARNING!
Danger from rotating impeller!
Stop the engine before installing
or removing the blower tubes!
Never perform any maintenance
or assembly procedures on this
machine while the engine is
running!
Nut
Swivel
Handgrip
Tube
Washer
85mm Clamp
Flexible Tube
Swivel Tube
Straight Tube Nozzle Tube
48003
Tube Assembly
Align the lock pins with
the lock slots, and push
the tubes together.
48004A
Lock Pin
Lock Slot
Rotate clockwise to lock
48004B
Bolt
5