2. Install the Power Shower. NOTE:
Verify that the Power Shower O-ring
and gasket are present and in good
condition and that the clean-out screws
are installed at each corner.
DO NOT operate the filter without the Power Shower in place. Hot oil will spray out of
the fryer and cause injury.
3. After the cooking oil has drained from
the frypot, pull the filter handle forward
(outward) to start the pump and begin
the filtering process. There may be a
slight delay before the pump activates.
4. The filter pump draws the cooking oil through the filter medium and circulates it back up to and
through the frypot during a 5-minute process called polishing. Polishing cleans the oil by
trapping solid particles in the filter medium.
5. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let
the filter pump run 10 to 12 seconds after the oil begins to sputter from the Power Shower
openings. Turn the filter off, remove the Power Shower and let it drain.
Install the Power
Shower in the frypot
to be filtered.