DISTRIBUTION FRAME CABLING
Connections to the DCS 70 system are made by way of a customer provided system
distribution frame (SDF). All connections are made via the SDF except for the serial data
ports, 240VAC mains and battery back up.
The KSU and Expansion Cabinet are each connected to the SDF using 2x25 pair AMP
Champ cables and 1x25 pair AMP Champ cable respectively. The retaining screw on the
AMP Champ connectors should be used to hold the connector in place. The 25 pair cables
should be routed via the cable brackets inside the DCS 70 KSU and clamped to the cable
anchoring points using nylon cable ties.. The 25 pair cables should be routed into the KSU
and Expansion cabinet from below. (See Fig 3.6)
Label each cable to correspond with the connector numbers.
Page 3-3