Modifying The 3Trkd70 And 6Trkd70 Cards For Use With Prs Hybrids; Modifying The 4Trk24 And 6Trk24 Cards For Use With Prs Hybrids - Samsung DCS 70 Installation Manual

Digital communications systems
Table of Contents

Advertisement

SAMSUNG DCS 70
INSTALLATION MANUAL
A square at the right hand end of the silkscreen HYB outline on the 3TRK and 6TRK cards
marks the pin 1 position.
A black triangle is printed on one side of the PRS and MPD hybrids. The triangle marks pin
1 of the hybrid.
The 3TRK and 6TRK boards must be modified before they can be used with PRS hybrids.
The modification involves soldering a wire link across the decoupling capacitors used for
MPD so that the PRS hybrid is connected directly to the line.
MODIFYING THE 3TRKD70 AND 6TRKD70 CARDS FOR USE WITH PRS
HYBRIDS
Solder wire links across the capacitors on each exchange line that will be used for PRS.
1.
(Two capacitors per line - see Table below)
Insert the hybrid into the required socket on the board ensuring that hybrids are fitted with
2.
the correct orientation.
Line
3 TRK Card Capacitors
1
2
3
4
5
6
MODIFYING THE 4TRK24 AND 6TRK24 CARDS FOR USE WITH PRS
HYBRIDS
The cards are supplied ready for use with MPD hybrids. i.e. the hybrid sockets are connected
to line via decoupling capacitors.
Solder wire links across the capacitors on each exchange line that will be used for PRS.
1.
(Two capacitors per line - see Table below)
Insert the hybrid into the required socket on the board ensuring that hybrids are fitted with
2.
the correct orientation.
Line
4 TRK24 Card Capacitors
1
2
3
4
5
6
C65 & C66
C67 & C68
C69 & C70
C104 & C105
C204 & C205
C304 & C305
C404 & C405
Page 4-7
th
10
January, 2000
6 TRK Card Capacitors
C25 & C26
C27 & C28
C29 & C30
C31 & C32
C33 & C34
C35 & C36
6 TRK24 Card Capacitors
C104 & C105
C204 & C205
C304 & C305
C404 & C405
C504 & C505
C604 & C605

Advertisement