When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when power
is turned on or after reset. Although the IDD operations are assured with the default values, the
operations are not always optimal for the system. To obtain the best performance, set the
parameters in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures. Refer to Chapter 4 of Fibre Channel
Interface Specifications for further details of the MODE SELECT and MODE SELECT
EXTENDED commands and specifying the parameters.
1.
At factory shipment of the IDD, the saving operation for the MODE
SELECT parameter is not executed.
parameters, the IDD operates according to the default value of each
parameter
2.
The model select parameter is not saved for each SCSI ID of but as the
common parameter for all IDs. In the multi-INIT System, parameter
setting cannot be changed for each INIT.
3.
Once parameters are saved, the saved value is effective as long as next
saving operation is executed from the INIT. For example, even if the
initialization of the disk is performed by the FORMAT UNIT command,
the saved value of parameters described in this section is not affected.
4.
When the IDD, to which the saving operation has been executed on a
system, is connected to another system, the user must pay attention to
that the IDD operates according to the saved parameter value if the
saving operation is not executed at installation.
5.
The saved value of the MODE SELECT parameter is assumed as the
initial value of each parameter after the power-on, the RESET
condition, or the BUS DEVICE RESET message. The INIT can change
the parameter value temporary (actively) at any timing by issuing the
MODE SELECT or MODE SELECT EXTENDED command with
specifying "0" to the SP bit in the CDB.
IMPORTANT
So, if the user does not set