On Machines With Drive System Md-4-57-220-Ce; Secure The Parameter Values (Drive System Md-4-57-220-Ce) - Pfaff 571 Instruction Manual

Hide thumbs Also See for 571:
Table of Contents

Advertisement

8

On machines with drive system MD-4-57-220-CE

.09.02
● Press and hold button and switch on machine
● Parameter 176 is displayed.
● Call up parameter 181.
A B
● Call up input level.
S
● Sew three stitchs with the pedal function.
● Turn handwheel in rotational direction until the needle is in position b.d.c.
● Note down the value shown in the display.
● Turn the handwheel in rotational direction until the needle point (approaching from above)
is on the upper edge of the needle plate.
A
● Confi rm entry.
● Call up parameter 192
A B
● Call up input level.
S
D
● Use button D+ to set the function to "off".
● Call up parameter level.
A B
● Call up parameter 181
D
C
● Call up input level.
S
B C D
● Enter the value you noted down previously.
● Press button "S" to exit input.
S
8
Secure the parameter values
.10
● Press and hold button and switch on
S
● Call up parameter 132.
A B
● Confi rm entry.
S
D
● Call up memory position (0, 1, 2, 3 or 4).
● Press and hold button until "SAv.E.ot" is displayed for a moment.
A
The values are now saved.
Installation and commissioning
(drive system MD-4-57-220-CE)
machine.
29