PROBLEM
Motor will not run.
Restricted air intake
D22171
CAUSE
Motor overload protection switch
has tripped
Tank pressure exceeds pressure
switch "cut-in" pressure.
Extension cord is wrong length or
gauge.
Check valve stuck open.
Loose electrical connections.
Possible defective motor or start-
ing capacitor.
Paint spray on internal motor
parts.
Pressure release valve on pres-
sure switch has not unloaded
head pressure.
Fuse blown, circuit breaker
tripped.
Dirty air filter.
20 - ENG
CORRECTION
Let motor cool off and overload
switch will automatically reset.
Motor will start automatically
when tank pressure drops below
"cut-in" pressure of pressure
switch.
Check for proper gauge wire and
cord length.
Remove and clean, or replace.
Check wiring connection inside
pressure switch and terminal box
area.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not oper-
ate the compressor in the paint
spray area. See flammable vapor
warning.
Bleed the line by pushing the lever
on the pressure switch to the "off"
position; if the valve does not
open, replace switch.
1. Check fuse box for blown fuse
and replace as necessary.
Reset circuit breaker. Do not
use a fuse or circuit breaker
with higher rating than that
specified for your particular
branch circuit.
2. Check for proper fuse. You
should use a time delay fuse.
3. Check for low voltage condi-
tions and/or proper extension
cord.
4. Disconnect the other electrical
appliances from circuit or
operate the compressor on its
own branch circuit.
Clean or replace. See Air Filter
paragraph in the Maintenance
section.