4. Brush
(1) Brushes that are worn beyond wear limit line, or oil
(2) When replacing ground brush, side the brush from brush
Wear
limit
line
1EN0292
5. Armature Coil Short Circuit Test
(1) Place armature on a growler.
(2) Hold a thin steel blade parallel and just above while
6EN0600
6. Armature Coil Ground Test
Check the insulation between ground commutator segment
and the armature coil core. If there should be no continuity.
6EN0601
7. Armature Coil Open Circuit Check
Check the continuity between segments. If there should be
continuity.
45
soaked, should be replaced.
holder by prying retainer spring back.
rotating armature slowly in growler. A shorted armature
will cause blade to vibrate and be attracted to the core.
Replace shorted armature.