Chapter 3
Points to note at installation
When attaching the terminal [1], make sure that the contact spring [2]
contacts as shown.
[1]
[2]

3.2 LASER EXPOSURE SYSTEM

3.2.1 Laser Scanner Unit

3.2.1.1 Preparation for Removing the Laser Scanner Unit

LBP3100 / LBP3010B
1) Removing the Upper Cover (page 3-2)Reference[Removing the Upper
Cover]
2) Removing the Left Cover (page 3-2)Reference[Removing the Left Cov-
er]
3) Removing the Right Cover (page 3-1)Reference[Removing the Right
Cover]
4) Removing the Front Cover (page 3-3)Reference[Removing the Front
Cover]

3.2.1.2 Removing the Laser Scanner Unit

LBP3100 / LBP3010B
1) Remove the scanner sub cover [1].
- 1 screw [2]
2) Remove the scanner cover [1].
- 3 screws [2]
3-14
[1]
[2]
F-3-44
[2]
3) Remove the laser scanner unit [1].
- 1 flat cable [2]
- 1 connecter [3]
- 4 screws [4]
- Do not disassemble the laser scanner unit because it needs adjustment.
0019-2196
0019-2197
Points to note at installation
When attaching the laser scanner cover [1], put the shutter lever [2] through
the hole [3] on the scanner cover.
[1]
F-3-45
[1]
[2]
F-3-46
[2]
[3]
[2]
[4]
[3]
[1]