Procedure 6.1 - Troubleshooting the Lower and Upper Data
Troubleshooting the Upper Data Cable
1.
Remove the four screws from the rear of the display housing that fasten the display front
panel to the display housing. Carefully, lift the display front panel off of the display housing
and disconnect the heart rate cable and upper data cable from the upper printed circuit
assembly. See Diagram 6.1.
Diagram 6.1 - Display Housing, with Front Display Panel Removed,
Heart Rate
Cable
2.
Remove the left hand and right hand cover sections per Procedure 7.1.
3.
Disconnect the upper data cable from the mid-point connector. See Diagram 6.2.
4.
Connect a known good data cable from the upper printed circuit assembly to the mid-point
connector.
5.
If the C776i now functions correctly, replace the upper data cable per Procedure XX. If the
C776i still functions incorrectly, replace the original upper data cable and continue with step
6.
Troubleshooting the Lower Data Cable
6.
Connect a known good data cable from the lower printed circuit assembly to the mid-point
connector. See Diagram 6.2.
7.
If the C776i now functions correctly, replace the lower data cable per Procedure XX. If the
C776i still functions incorrectly, replace the original lower data cable and continue with step
8.
Cables and Mid-Point Connector
C776i Stairclimber
Rear Cover
Mounting
Screw
Upper
Data Cable