Samsung AQ12?5(6)MB Service Manual page 5

Room air conditioner
Table of Contents

Advertisement

Table
(Cont.)
Item
Type
Cooling
Heating
Dehumiditying
Cooling
Air volume
Perfor-
Heating
mance
Cooling
Noise
Heating
Cooling
Energy efficiency ratio
Heating
Power
Cooling
Power Consumption
Heating
Cooling
Operating Current
Heating
Cooling
Power
Power factor
Heating
Starting current
Length
Power cord
Number of core wire
Fuse capacity
Outer
Width x Height
Dimension
x Depth
Weight
Liquid
Refrigerant pipe
GAS
Drain hose
Size
Compressor
Type
Motor Type
Rated output
Blower
Type
Motor Type
Rated output
Heat exchanger
Refrigerant control unit
Freezer oil capacity
Refrigerant to change(R-22)
Protection device
Cooling test Condition
Maximum operation Condition
2-3
Model
AQ12 A(B)ME / SH12Z A(B)
Indoor unit
Outdoor unit
Wall-mounting
12000 (3.5)
BTU/h(KW)
13000 (3.8)
BTU/h(KW)
\
1.9
/h
7.4
m
3
/min
7.9
41
dB
41
BTU/h•W
(2.99)
(W/W)
(2.99)
V-Hz
1-220 / 240-50
1170
W
1270
5.4
A
5.5
96.0
%
96.0
A
30
m
-
-
A
250V-10 / 16A
mm
790 x 245 x 165
740 x 530 x 230
31.1 x 9.6 x 6.5
29.1 x 20.6 x 9.1
inch
7.7
ø6.35 x 5
mm x L(MT)
mm x L(MT)
ø12.7 x 5
D x L(mm)
ø18 x 2000
Rotary
-
-
Cross-flow
Propeller
Resin
15
W
2ROW 12STEP
1ROW 24STEP
CAPILLARY TUBE
410
1000
RAC12030-9622
INDOOR UNIT : DB27°C WB19°C
INDOOR UNIT : DB32°C WB23°C
AQ09 5(6)MED/SH09Z 5(6)D
Indoor unit
Outdoor unit
Wall-mounting
9000 (2.64)
10000 (2.85)
1.4
23.0
6.0
23.0
6.7
53
38
53
38
8.91
10.87
1-220 / 240-50
1010
920
4.4
4.0
99.8
99.8
30
-
-
250V-10 / 16A
790 x 245 x 165
660 x 497 x 235
31.1 x 9.6 x 6.5
26 x 19.6 x 9.3
35.0
7.7
ø6.35 x 5
ø9.52 x 5
ø18 x 2000
Rotary
-
-
-
-
Cross-flow
Propeller
steel
Resin
25
15
2ROW 12STEP
1ROW 22STEP
CAPILLARY TUBE
360
610
RAC 12054-9622
AQ07 5(6)MED / SH07Z 5(6)D
Indoor unit
Outdoor unit
Wall-mounting
7500 (2.20)
8000 (2.34)
0.9
18
5.6
18
5.5
51
35
51
35
9.74
10.959
1-220 / 240-50
770
730
3.4
3.2
94.4
95.0
30
-
-
250V-10 / 16A
790 x 245 x 165
660 x 497 x 235
31.1 x 9.6 x 6.5
26 x 19.6 x 9.3
29
7.7
ø6.35 x 5
ø9.52 x 5
ø18 x 2000
Rotary
-
-
-
-
Cross-flow
Propeller
steel
Resin
25
15
2ROW 12STEP
1ROW 22STEP
CAPILLARY TUBE
360
520
RAC 12086-9622
OUTDOOR UNIT : DB35°C WB24°C
OUTDOOR UNIT : DB43°C WB26°C
Samsung Electronics
18
18
50
50
29
-
-
steel
25

Hide quick links: