Specifications

Max Water Supply
Pressure kPa
Maximum Thermostat Setting (ºC)
ECO Operating Temperature (ºC)
Storage Capacity (Litres)
Booster Capacity (Litres)
Anodes
Water Connections
T&PR Valve
Sunstat Valve
Inlet x Cylinder x Cold pipe
Weight (Kg)

Solar Hiline Operation

The Hiline solar system operates on the thermosiphon principle. As water in the collector/s
gains heat from solar radiation it rises to the top of the collector/s and then into the tank via
the hot pipe. As the heated water from the collector/s flows to the tank, cold water from the
bottom of the tank is able to return back into the collector/s, via the Sunstat valve and cold
pipe, to be heated. The Sunstat valve is a temperature operated isolating valve designed
to stop the flow of water back to the collectors when the water temperature in the tank
reaches approximately 75ºC.
An auxiliary electric heating unit and thermostat is incorporated in the design of the
storage cylinder to provide back up heating during periods of low solar contribution, cloudy
weather or high hot water demand.
The Hiline solar system is not suitable for use in frost prone areas.
TM005 Rheem Solar Hiline Service Instructions REV D
D.O.I 20/02/2009
This document is stored and maintained electronically by
With ECV
Without ECV
Quantity
Length (mm)
Inlet
Outlet
Hot pipe
Cold Pipe
Diameter
Rating kPa
Empty
Full
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled".
52S160
680
800
70
78-88
160
80
1
823
GB ½/15
RP ¾/20
Tank
Collector
GB ¾/20
M33
GB ¾/20
M33
RP ½/15
1000
GB½/15 x RP1¼/32 x
GB¾/20
103
265
6
Model
52S300
680
800
70
78-88
300
160
1
1616
GB ½/15
RP ¾/20
Tank
Collector
GB ¾/20
GB ¾/20
RP ½/15
1000
GB½/15 x RP1¼/32 x
GB¾/20
161
455
M33
M33