Fault finding (Chart 7)

7
Is the leak from
the tank?
NO
Is the leak from a
collector connection?
NO
Is the leak from the
collector?
YES
Is water running from
the bottom of the
collector?
YES
Is the system in an
area that is prone to
frost?
YES
NO
Replace the collector.
NOTE: All installations above 600 metres are not
covered by warranty for frost damage to the collectors
TM005 Rheem Solar Hiline Service Instructions REV D
D.O.I 20/02/2009
This document is stored and maintained electronically by
YES
Replace o-rings and
YES
connectors if damaged
or cracked.
NO
Condensate may be
NO
forming in the collector.
This is a normal condition.
YES
Is the cold pipe a 1"
insulated pipe?
NO
Replace the collector.
No warranty applies if leak
is due to frost.
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled".
Leaking water
Is the leak from the
T&PR valve?
NO
Is the leak from the
anode thread?
NO
Is the leak from the
heating unit gasket?
NO
Is the leak from a
plumbing fitting?
NO
Is the leak from the
Sunstat valve?
24
YES
YES
Reseal the anode.
Replace the heating unit
YES
Reseal the plumbing
YES
Replace the Sunstat
YES
Tank may be leaking, feel
NO
for hot spots on the jacket.
3.1
gasket.
fittings.
valve.
Replace tank.