Fault Finding (Chart 8) - Rheem 52S160 Service Instructions Manual

Solar hiline water heater
Table of Contents

Advertisement

Fault Finding (Chart 8)

8
Is the noise only evident
when hot water is being
drawn off during periods of
high solar gain?
NO
Is the noise only evident
when electric heating cycle
is on?
NO
Is the noise water hammer?
NO
Is the noise only evident
when water is flowing
through the water heater?
YES
Is the water pressure above
700kPa?
TM005 Rheem Solar Hiline Service Instructions REV D
D.O.I 20/02/2009
This document is stored and maintained electronically by
Noisy water heater
YES
YES
YES
NO
NO
YES
25
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled".
Noise is caused by FLASH STEAM.
Refer to explanation in Hot Water
Physics section.
Check for:
Mineral build up on the heating unit
loop - replace heating unit.
Poor quality water supply i.e. dam
water sludge - flush tank.
Refer to water hammer explanation in
common complaints section.
Check all other appliances that can
generate noise i.e. washing machine,
dishwasher, ball cocks etc.
Check for a faulty stop cock, non-
return valve, ECV or T&PR valve.
Check for restrictions in pipe work,
faulty valves, loose plumbing, other
appliances i.e. washing machine or
dishwasher. Fit PLV if required.