ADJUSTMENTS
Ice Bridge Thickness
Caution: Do not make the bridge too thin or
the machine will not harvest properly. Bridge
thickness adjustments are not covered by
warranty.
Shut machine off.
Access the ice thickness sensor.
Check gap between metal tip and evaporator
grid. Small cube standard gap is 5 mm (3/16"),
medium cube standard gap is 5,5 mm (7/32"). To
set, place a 5 mm - 3/16" (small cube) or 5,5 mm
- 7/32" (medium cube) drill bit between sensor tip
and evaporator to check. Adjust gap using
adjustment screw.
Restart unit and check ice bridge. Repeat as
needed.
WATER PURGE SETTING
The water purge is factory set to the Automatic setting. The setting can be changed to one of 5 manual
settings or placed on automatic. The purge setting shows in the Code Display.
(very soft
≤ 4°f)
Soft
water
(5 ≤ °f ≤ 9)
(10 ≤ °f ≤ 16)
To set:
Switch the machine OFF by holding the Off
button in until a number or the letter A shows on
the display.
Press and release the On button repeatedly until
the number on the display corresponds to the
desired setting.
Press and release the Off switch again to return
to the normal control state.
Very hard
Hard
water
water
(17 ≤ °f ≤ 22)
(°f ≥ 23)