5-3. COMPONENT OUT Pb Level Adjustment
(D1 BETACAM) (VD-036 board)
Mode
E-E
Signal
No Signal
Measurement Point
Pb/Cb terminal of COMPONENT
OUT jack (75 Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
9A
Pb level: A = 756 ± 10 mVp-p
Specified value
Adjusting method:
Order Page Address Data
1
2
3
4
5
C
9A
6
C
9A
7
8
9
10
11
Fig. 6-2-11
HVR-M15J/M15U/M15N/M15E/M15P/M15C
Procedure
Perform "Preparations".
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "60i".
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Change the data and set the
Pb signal level (A) to the
specified value.
Press PAUSE (Write) button.
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "50i".
Check the Pb signal level (A)
to the specified value.
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Perform "Processing after
Complete Adjustment".
A
H
5-4. COMPONENT OUT Pr Level Adjustment
(D1 BETACAM) (VD-036 board)
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Adjusting method:
Order Page Address Data
1
2
3
4
5
C
9B
6
C
9B
7
8
9
10
11
6-54
E-E
No Signal
Pr/Cr terminal of COMPONENT
OUT jack (75 Ω terminated)
Oscilloscope
C
9B
Pr level: A = 756 ± 10 mVp-p
Procedure
Perform "Preparations".
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "60i".
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Change the data and set the
Pr signal level (A) to the
specified value.
Press PAUSE (Write) button.
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "50i".
Check the Pr signal level (A)
to the specified value.
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Perform "Processing after
Complete Adjustment".
H
Fig. 6-2-12