5. COMPONENT OUT Adjustment (D1 BETACAM)
5-1. Preparations
Perform the following data setting before the "COMPONENT OUT
Adjustment (D1 BETACAM)".
Switch setting
1) DISPLAY OUTPUT switch .................................... OFF
2) INPUT SELECT switch ................... VIDEO (except DV)
3) HDV/DV SEL (IN/OUT REC menu) .................... HDV
4) HDMI/CMPNT (IN/OUT REC menu) .................... 480i
5) DOWN CONVERT (IN/OUT REC menu) ... SQUEEZE
Order Page Address Data
1
0
2
0
3
3
(13)
8
4
(18)
5
0
6
8
7
Note:
For the bit values, refer to "6-3. SERVICE MODE", "3-
4. 4. Bit value discrimination".
A
HVR-M15J/M15U/M15N/M15E/M15P/M15C
Procedure
01
01
10
01
Set the bit value of bit1 is
CF
"1", and press PAUSE
button. (Note)
Set the bit value of bit7 is
00
"1", and press PAUSE
button. (Note)
10
00
Set the bit value of bit1 is
00
"1", and press PAUSE
button. (Note)
Wait for 5 sec.
H
Fig. 6-2-10
5-2. COMPONENT OUT Y Level Adjustment
(D1 BETACAM) (VD-036 board)
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Adjusting method:
Order Page Address Data
1
2
3
4
5
C
6
C
7
8
B
9
10
11
12
13
6-53
E-E
No Signal
Y terminal of COMPONENT OUT
jack (75 Ω terminated)
Oscilloscope
C
99
Y level: A = 1000 ± 10 mVp-p
Sync level: B = 286 ± 10 mVp-p (NTSC)
B = 300 ± 10 mVp-p (PAL)
Procedure
Perform "Preparations".
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "60i".
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Change the data and set the Y
99
signal level (A) to the
specified value.
99
Press PAUSE (Write) button.
Check the sync signal level
(B) to the NTSC specified
value.
Set the HOLD switch of
adjustment remote com-
mander to "OFF" (NORMAL
position).
Set the 60i/50i SEL (OTH-
ERS menu) to "50i".
Check the Y signal level (A)
to the specified value.
Check the sync signal level
(B) to the PAL specified
value.
Set the HOLD switch of
adjustment remote com-
mander to "HOLD" (SER-
VICE position).
Perform "Processing after
Complete Adjustment".