TROUBLESHOOTING
Symptom
Battery icon on LCD on
transmitter
LCD display is blank
LCD display shows
"funny" display
Appliance does not
come on
Blower is not on after
the fireplace is turned
on
40
Figure 56
Causes
Low Battery
The transmitter did not match with the
receiver.
Transmitter measures temperature
exceeding 99°F and shows "HI" on LCD.
Distance between the transmitter and
receiver is more than 30 feet.
Blower setting is off.
Blower delay setting is set too high.
TOUCH SCREEN REMOTE CONTROL OPERATION
Action
Replace batteries. Change batteries every
6 months.
Check battery installation or replace batteries.
Reset the transmitter (see "Resetting the
Transmitter" section).
Make sure the transmitter has learned to the
receiver.
Move transmitter to a cooler place and wait
until temperature drops below 99°F degrees.
Make sure the opening distance is less than
30 feet.
Press FAN key to select Fan speed you
desire.
Press and hold FAN key to set desired ON/
OFF delays. This is done in minutes.