Vermont Castings WDVST500NTSCSB Installation And Operating Instructions Manual page 36

Wdv see-thru direct vent gas fireplace
Table of Contents

Advertisement

WDV See-thru Gas Fireplace
Setting Privacy Code on Transmitter:
Figure 45
The remote transmitter privacy code is preset in factory. In
the event of activation or interference from other nearby
transmissions, change the code using the following proce-
dures (learn function must be performed after changing the
code):
1. Press the ON/arrow button and the
TIMER button at the same time to
enter privacy code setup mode.
2. The setup display is shown in the
figure. The four digits on the top
stand for the privacy code (as the
actual DIP switches on Ambient's
previous remotes). The default
values of the four digits will be all
"1" (ON).
3. The first digit will be flashing upon
entering the setup mode. Push the
ON button to toggle its value between "0" (OFF) and
"1"(ON), and push the "OFF" button to jump to the next
digit. The next digit will then start flashing and the first
one stops flashing. Set up the four digits to your choice.
4. After setting up all the four digits, push "OFF" to finish
the process and return to the previous mode.
5. The Signature Command control board then needs to
re-learn the new setting.
Performing Learn Function
1. The RF receiver button on the control board in the fire-
place must be in the on position before the learn func-
tion can begin. Figure 46. With the Command Center
master switch in the ON position, use paper clip to de-
press the recessed button on Control Board, one beep
for RF receiver ON or two beeps for RF receiver OFF.
2. Holding the OFF button on the Command Center while
turning on the master switch will activate the learn
function for the transmitter.
3. After the above operation, two beeps will be given and
the green LED on the Command Center will flash for
10 seconds.
4. During the 10 sec-
onds,
press
the
OFF
button
on
the transmitter to
learn. Another two
beeps will be given
to confirm a suc-
cessful
learning.
Figure 47
36
Figure 45
FP2649
set privace code
RF
Receiver
ON/OFF
Figure 46 - Control Board
TOUCH SCREEN REMOTE CONTROL OPERATION
LED
OFF
Battery Door
Figure 47 -
Command Center
FP2650
command ctr ctrl brd
Do not use two (2) or more remote control sys-
tems in the same area with the same privacy
code setting, as they will communicate with
each other. This may cause the appliances to
malfunction.
Resetting the transmitter:
If the transmitter is not working properly, reinstall the bat-
teries to reset the transmitter.
1. Pull out at least one of the batteries.
2. Press any key on the screen to discharge.
3. Wait for 10 seconds and reinstall the batteries.
Pushing and holding any key for more than 10 seconds
until the display refreshes will also reset the transmitter.
FUNCTIONS AND OPERATIONS
General:
The TSFSC Remote Control has four (4) operating modes:
Manual, Timer, Thermostatic and Smart Mode
stat. The control system can be set to temperature range
between 45° F and 90° F. The blower speed and flame
height can be adjusted in the manual, timer and thermo-
static mode. The Smart Mode
cally adjust flame height and blower speed according to
the difference between Set and Room temperatures.
The transmitter will operate the remote receiver from 1
foot to a maximum of 30 feet. The distance is reduced
when batteries are low.
Manual Mode
Figure 48
In this mode, the TIMER button and the THERMO but-
ton will only display "TIMER" and "THERMO", respec-
tively without showing the time and the SET temperature.
Pressing the ON/up and OFF/down buttons will change
the flame height if none of the menu buttons (TIMER,
THERMO, LIGHT, FAN, AUX) are pressed and flashing.
ON
Master Switch
FP2650
Front Panel Bezel
Optional
®
thermostat will automati-
®
thermo-
20306746

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wdvst500ptscsb

Table of Contents