Brother MFC-3340CN Service Manual page 334

Facsimile equipment
Hide thumbs Also See for MFC-3340CN:
Table of Contents

Advertisement

Selector
No.
1
First transmission speed choice
for fallback
|
3
4
Last transmission speed choice
|
for fallback
6
7
V.34 mode
8
V.17 mode
NOTE: Selector 7 takes effect only in models supporting V.34 mode.
l
Selectors 1 through 6: First and last choices of transmission speed for fallback
These selectors are used to set the MODEM speed range. With the first transmission speed choice
specified by selectors 1 through 3, the machine attempts to establish the transmission link via the
MODEM. If the establishment fails, the machine automatically steps down to the next lowest speed
and attempts to establish the transmission link again. The machine repeats this sequence while
stepping down the transmission speed to the last choice specified by selectors 4 through 6.
If the MODEM always falls back to a low transmission speed (e.g., 4,800 bps), set the first
transmission speed choice to the lower one (e.g., modify it from 12,000 bps to 7,200 bps) in order to
deactivate the high-speed MODEM function and reduce the training time for shorter transmission
time.
Generally, to save the transmission time, set the last transmission speed choice to a higher one.
WSW19
(Transmission speed setting)
Function
App. 4-22
Setting and Specifications
No. 1
2
3
No. 4
5
6
0
0
0
:
0
0
1
:
0
1
0
:
0
1
1
:
1
0
0
:
1
0
1
:
1
1
0
:
1
1
1
:
0: Permitted
0: Permitted
2,400 bps
4,800 bps
7,200 bps
9,600 bps
12,000 bps
14,400 bps
1: Prohibited
1: Prohibited
Confidential

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc3240cFax1940cnFax1840cFax1835c

Table of Contents