Remote Control Operation; Maintenance - Bosch DS304 Installation Instructions Manual

Passive infrared (pir) detector
Table of Contents

Advertisement

DS304| Installation Instructions |
5.5
Setup for Remote Control Panel
Alarm Memory and LED Operation
Using S/U and WT Inputs
Table 3:
User DIP Switch Selection
DIP
Function
Switch
1
Select
Walk Test
polarity
3
Select
Set/Unset
polarity
Ensure the control terminal program jumper is configured as
shown in Item 1 of Figure 5 on page 3 (refer to Section 5.1
Program Jumper for the S/U Control Terminal on page 4).
6.0

Remote Control Operation

Table 4:
Remote Control Operation
Control Line Status
Arming
Walk Test
Terminal
Terminal
Status
Status
Set
OFF or ON
Unset
OFF
ON
Transition
OFF or ON
from Unset
to Set
6.0 Remote Control Operation
ON
OFF
Low (0 V) =
High (12 V) =
Walk Test
Walk Test
active
active (default)
Low (0 V) =
High (12 V) =
Unset
Unset (default)
High (12 V) =
Low (0 V) =
Set
Set (default)
Detector
LED Status
Status
Memory
OFF
ready
Stored
Rapid flashing
alarm
(2 Hz)
No stored
OFF
alarm
Slow flashing
Power up
(0.5 Hz)
Alarm
ON for
activity
4 sec
No alarms
OFF
Memory
OFF
cleared
7.0
Setup and Walk Testing
Enable the LEDs before performing a
Walk Test.
1. Replace the cover and insert the cover tamper screw
(if desired).
2. Apply power to the unit.
3. Wait at least 2 min for the detector to stabilize and
no motion is detected (Figure 8).
Figure 8: Walk Testing
Walk test across the pattern.
4. Watch the LED as you walk to the farthest edge of
the coverage pattern. Walk closer to the detector by
crossing the pattern.
The LED lights when it detects you crossing the
coverage pattern.
5. Repeat from the other side.
If the desired range is not achieved, try angling the
mirror up or down to assure the coverage pattern is
not aimed too high or too low.
8.0

Maintenance

At least once a year, check the range and coverage
according to Section 7.0 Setup and Walk Testing. To
ensure continuous operation, instruct the end user to
walk through the outer edge of the coverage area daily
and observe the LED operation (if used). This also
assures an alarm output prior to arming.
Bosch Security Systems | 1/05 | 4998122424F