USING THE SECURITY FUNCTION

This function is available when the inputs 1, 2, and/or 3 of
*
this station are set to "SECURITY" in the [INSTALL] menu
window during installation, and a sensor is connected to
each of the inputs.
When this station's "Security" is turned on, an alarm is
sounded when a sensor is triggered.
Choose either "ARMED" or "ARMED AWAY".
■ ARMED
Security mode when you are present.
The alarm gets enabled when the security mode is turned
active.
■ ARMED AWAY
Security mode when you leave home/offi ce. Set a delay time
for the alarm to enable after the security mode is activated.
To activate security mode
1
Touch
SECURITY from HOME window.
2
Select sensor S1, S2, or S3. Touch
activate.
All sensors are set to "ENABLE" by default.
*
3
Select either
ARMED or ARMED AWAY .
The security mode is activated and the SECURITY icon
from HOME window turns in red.
ARMED AWAY , there is a delay before
When setting
*
the system is armed/disarmed.
See page.14 ("Setting the EXIT DELAY SETTING and
RETURN DELAY SETTING") if timing adjustments are
necessary.
If "S1", "S2" and/or "S3" has turned red:
*
ARMED AWAY is selected, the alarm will
When
sound after the delay time elapses.
ARMED
cannot be selected.
NOTES:
ENABLE to
To deactivate security
Touch SECURITY from HOME window.
The color of SECURITY icon changes from red to blue.
To stop alarm
When "ARMED AWAY" mode is activated and the delay time
*
is set; if a sensor is triggered before the delay time elapses,
the preliminary alarm sounds. The alarm sounds after the
delay time elapses.
[When there is no ALARM PIN]
Touch RESET .
[When there is an ALARM PIN]
1
2
Retrieve the ALARM PIN
Press and hold the [HOME] button for more than 2 seconds
while the alarm is sounding.
This method is unavailable until the delay time is reached.
*
The ALARM PIN is displayed on the screen for 2 seconds.
When a sensor is triggered
A message is displayed, the sensor ID number is shown,
the status LED blinks in red and an alarm sounds on all of
the master and sub master stations.
Sensor
Alarm
The alarm sounds in the maximum volume (10) even if the volume
of call tone is set to 0.
Door station 1 also sounds alarm and turns on the white LED.
All the functions of this station are available while security is on.
However, no setting changes for security are possible.
When the alarm is triggered, no other input for security is disabled
until the alarm stops.
Touch
RESET .
Enter the ALARM PIN and touch
This station turns into the standby mode.
*
If a wrong ALARM PIN has been entered, an error
message is displayed. Enter correct ALARM PIN. (See
page 14 for ALARM PIN settings).
Blinks in red.
ENTER .