  • Page 1 Electronic/Mechanical Thermostat Electronic/Mechanical Thermostat Electronic/Mechanical Thermostat Owner’s Guide and Installation Manual Model 40135 40137 44017-01 20121101 ©2012 Hunter Fan Co.
  • Page 2 Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at 1-888-830-1326.
  • Page 3: Table Of Contents

    Table of Contents Important Information ........5 Tools ..............6 Uninstalling the Existing Unit ......9 Installing the Thermostat ........ 12 Installing the Wall Plate ........14 Connecting the Wires ......15 Attaching the Thermostat ....17 Operation ............20 Indicators & Adjustments ........ 22 Troubleshooting ..........
  • Page 4 Electronic/Mechanical Thermostat Models 40135 / 40137 Congratulations! ® Thank you for choosing a Hunter thermostat. ® Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete...
  • Page 5: Important Information

    IMPORTANT INFORMATION This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Air Conditioner Electric Furnace This thermostat is not designed for heat pump systems or 110/220V baseboard heating systems.
  • Page 6: Tools

    TOOLS This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head Screwdriver ..................Small Phillips-head Screwdriver ..................Hammer ..................Electric drill and 3/16” bit ..................Two fresh 1.5 Volt (AA) size alkaline batteries ..................
  • Page 7 NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection.
  • Page 9: Uninstalling The Existing Unit

    UNINSTALLING THE EXISTING UNIT 1. Turn the system power OFF from the existing thermostat. Turn the power to the HVAC system OFF at the main power panel or at the furnace. 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.)
  • Page 10 label the wire If your existing with this sticker: thermostat is marked... RH / R / VR / 4 24 Volt 24 Volt Cool RC / VC Y / C* / M air conditioning compressor W / H heating G / F * See pg.
  • Page 11 UNINSTALLING THE EXISTING UNIT, CONT. 4. Using the provided stickers, label each wire according to the chart. (If the terminals are not labeled, contact a qualified HVAC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification.
  • Page 12: Installing The Thermostat

    INSTALLING THE THERMOSTAT 1. Remove the new thermostat from the back plate by pulling the two halves apart. Wall Plate Thermostat...
  • Page 14: Installing The Wall Plate

    2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing ® holes, level the wall plate and mark the wall for two holes.
  • Page 16: Connecting The Wires

    CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper.
  • Page 17 HE/HG Switch...
  • Page 18: Attaching The Thermostat

    ATTACHING THE THERMOSTAT 4. Locate the HE/HG Switch on the back of the thermostat. Set the switch to HG for a gas furnace or oil burner. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 5.
  • Page 20 System Thermometer Switch Set Temperature Slider SYSTEM COOL HEAT AUTO Battery Indicator Switch...
  • Page 21: Operation

    OPERATION 1. Set the Set Temperature Slider to the desired temperature. 2. The System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. The Fan Switch should normally be located in the Auto position. To run the fan continuously, slide the Fan Switch to the On position.
  • Page 22 INDICATORS AND ADUSTMENT 1. The Thermometer indicates the room temperature. 2. The Battery Indicator displays two stages of battery conditions. The first warning is the Weak Battery Warning, indicated by the Battery Indicator flashing once approximately every second. When this warning appears, install two fresh AA alkaline batteries at your earliest convenience.
  • Page 23 Span Adjust SPAN...
  • Page 24: Indicators & Adjustments

    INDICATORS AND ADJUSTMENTS, CONT. Your thermostat is preset to cycle your system off and on at 1 F above and below the Set Temperature. For maximum system efficiency and a sustained comfortable temperature your system should cycle 3-5 times per hour. If your system is cycling either too often or not often enough, then use a small Phillips-head screwdriver to turn the Span Adjust left or right to change the cycle time.
  • Page 25: Troubleshooting

    TROUBLESHOOTING 1. My heating or cooling will not turn on or off. 1a. Check the HE/HG Switch to ensure it is set to the correct position. 1b. Wait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor. 1c.
  • Page 26 TROUBLESHOOTING Is there help on the web? Yes. Visit http://www.HunterFan.com for more information..................Can I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at 1-888-830-1326.
  • Page 27 4- w i r e Heat / Cool Sys t em Cool Heat Rel ay Heat / Cool Cont act or Rel ay orVal ve 24V Suppl y 5-wire H eat/C ool Sy stem Cool Heat Rela Cool Heat Contact or Rel a y or V alve 24V Supply...
  • Page 28: Wiring Diagrams

    WIRING DIAGRAMS 2- w i r e Heat Onl y Sys t em Heat Rel ay Heat 24V or orVal ve M i l l i vol t Suppl y 3- w i r e Heat Onl y Sys t em Rh W Heat Rel ay Heat 24V...
  • Page 29 WIRING DIAGRAMS, CONT. 3- w i r e Cool Onl y Sys t em Cool Cool 24V Cont act er Rel ay Suppl y...
  • Page 30 © 2012 Hunter Fan Company...