Kenwood TK-8180 Service Manual page 41

Kenwood uhf fm transceiver service manual
Hide thumbs Also See for TK-8180:
Table of Contents

Advertisement

Item
Condition
11. Max DEV
1) Adj item : [n DEV]
adjust
Adjust : [✳✳✳]
AG : 1kHz/50mV at MIC terminal
Deviation meter filter
LPF : 15kHz
HPF : OFF
2) Adj item : [nL DEV] →
• Narrow
[nC DEV] → [nH DEV]
Adjust : [✳✳✳]
PTT : ON
• Wide 4k
3) Adj item : [s DEV]
Adjust : [✳✳✳]
PTT : ON
• Wide 5k
4) Adj item : [w DEV]
Adjust : [✳✳✳]
PTT : ON
12. MIC
[Panel test mode]
sensitivity
1) CH-Sig : 1-1
check
AG : 1kHz/5mV at MIC terminal
(Wide 5k only)
PTT : ON
13. QT deviation 1) Adj item : [n QT]
adjust
Adjust : [✳✳✳]
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [nL QT] →
• Narrow
[nC QT] → [nH QT]
Adjust : [✳✳✳]
PTT : ON
• Wide 4k
3) Adj item : [s QT]
Adjust : [✳✳✳]
PTT : ON
• Wide 5k
4) Adj item : [w QT]
Adjust : [✳✳✳]
PTT : ON
14. DQT
1) Adj item : [n DQT]
deviation
Adjust : [✳✳✳]
adjust
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [nL DQT] →
• Narrow
[nC DQT] → [nH DQT]
Adjust : [✳✳✳]
PTT : ON
• Wide 4k
3) Adj item : [s DQT]
Adjust : [✳✳✳]
PTT : ON
• Wide 5k
4) Adj item : [w DQT]
Adjust : [✳✳✳]
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Front
panel
panel
Deviation
Front
Modular
meter
panel
MIC jack
Oscilloscope
AG
AF VTVM
Front
panel
TK-8180
Adjustment
Parts
Method
± 0.10kHz
[ ],[ ] 2.10kHz
(According to the
larger +, –)
± 0.10kHz
3.30kHz
(According to the
larger +, –)
± 0.10kHz
4.20kHz
(According to the
larger +, –)
Check
2.5~3.5kHz
± 0.05kHz
[ ],[ ] 0.35kHz
± 0.10kHz
0.60kHz
± 0.10kHz
0.75kHz
± 0.05kHz
0.35kHz
± 0.10kHz
0.60kHz
± 0.10kHz
0.75kHz
Specifications/Remarks