LIGhTING

The refrigerator is provided with a battery power interior light.
The battery box is at the rear of the refrigerator. Four batteries,
type D (R20) 1.5 volts are to be used.

ShUT Off - STORAGE PROCEDURE

To shut off the refrigerator, turn knob (A) to "OFF" position.
If the refrigerator will not be in operation for a period of weeks,
it should be emptied, defrosted, cleaned and the doors left ajar.
The ice tray should also be dried and kept outside the cabinet.
NOTE: To avoid running down the batteries to the interior
light during defrosting and storage periods, use a tape to close
the light switch or remove the lamp bulb. The batteries can also
be removed from the battery box at the rear of the refrigerator.
NOTE: Sodium chromate is used for corrosion protection
(less than 2 weight % of coolant).
The user should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly.
A qualified technician who is familiar with LP gas systems and refrigerators should only perform the service.

PERIODIC mAINTENANCE

To keep your refrigerator operating efficiently and safely, peri-
odic inspection and cleaning of several components is recom-
mended once or twice a year.
It is important to keep the area at the back of the refrigerator
clean. Clean the coils on the back of the refrigerator. Use a soft
bristled brush to dust off the coils. It is important to keep the
refrigerator area free from combustible material, gasoline and
other flammable vapors or liquids.
The following maintenance is required once or twice a year, but
should only be done by a qualified serviceman who is familiar
with LP gas systems and refrigerators.
OPERATING INSTRUCTIONS
mAINTENANCE & SERVICE
Check all connections in the LP gas system
Check all connections in the LP gas system (at the back of the
refrigerator) for gas leaks. The LP gas supply must be turned
on. Apply a non-corrosive bubble solution to all LP gas connec-
tions. The appearance of bubbles indicates a leak and should
be repaired immediately by a qualified serviceman who is
familiar with gas system and refrigerators.
!
EXPLOSION hAZArD. Never use an open
flame to check for gas leaks. Failure to heed this
warning could cause an explosion resulting in
death or severe personal injury.