Main Procedure - Optoma HD710 Service Manual

Table of Contents

Advertisement

3-2 Main Procedure

No
Symptom
1
No Power
2
Auto Shut Down
3
Image Flicker
- Ensure the Power Cord and AC Power Outlet are securely
connected
- Check Lamp Cover and Interrupt Switch
- Ensure all connectors are securely connected and aren't
broken
- Check Lamp Driver
- Check LVPS
- Check Main Board
- Check LED Status
a. Lamp LED Light
- Check Lamp
- Check Lamp Driver
- Check Main Board
b. Temp LED Light
- Check Thermal Switch
- Check Fan
c. Color Wheel
- Check Color Wheel
- Check Photo Sensor
- Do "Reset(All data)" of the OSD Menu
- Ensure that the signal cables and source are work as well
- Check Lamp Module
- Check Color Wheel
- Check DMD Board
- Check Main Board
HD71/HD710/HD75
Procedure
Confidential
3-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd71Hd75

Table of Contents