Main Procedure - Optoma EP758 Service Manual

Hide thumbs Also See for EP758:
Table of Contents

Advertisement

3-2

Main Procedure

3-2.1
Coretronic Corporation
Power Troubleshooting
A.
Is LED Indicator OK?
-
Check the Power cord and AC power outlet.
-
Check the Keypad cable has broken or not.
-
Check if all the wires are connected well inside.
-
Check the Ballast.
-
Check the Main board.
-
Check the Keypad board.
B.
Is Fan Working After Press Power/Standby Button?
-
Check the Keypad cable has broken or not.
-
Check if all the wires are connected well inside.
-
Check the Thermal board.
-
Check the Main board.
-
Check the Fan.
C.
Is Lamp Lit?
-
Check the Lamp cover assembly OK or not.
-
Check thay have the sound of Lamp ignitor output from Unit or not.
-
Check if the cable of Interrupt Switch is connected well.
-
Check the DMD board.
-
Check the Lamp module.
-
Check the Ballast.
3-2
EP758/EP759