Sharp MX-M350 Service Manual page 184

Hide thumbs Also See for MX-M350:
Table of Contents

Advertisement

SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 0-18, AND PRESS START.
0.TRAY SELECT
1
3.OC_AE
64
6.OC_PHOTO
64
7.SPF1_AE
64
10.SPF1_PHOTO
64
11.SPF2_AE
64
14.SPF2_PHOTO
64
15.CIS_AE
64
18.CIS_PHOTO
64
Select other than 0 - 2,
and press [START] key.
SIMULATION 46-18
GAMMA SETUP. INPUT VALUE 0-127, AND PRESS START.
3.OC_AE
Select 1,
and press
Press [START] key.
[START] key.
SIMULATION 46-18
GAMMA SETUP. NOW PRINTING.
Select 0, and press [START] key.
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 1-5, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
Select 2, and
press [START] key.
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 3-14, AND PRESS
START.
(EXP.LEVEL SELECT)
3.AUTO
4.1.0
6.3.0
7.4.0
9.AUTO(H)
10.1.0(H)
12.3.0(H)
13.4.0(H)
46-19
Purpose
Adjustment
Function
Used to set the auto mode operation specifications
(Purpose)
in each mode (copy, scan, FAX).
Item
Picture quality
Operation/Procedure
(Toner save operation YES/NO setting in the auto mode)
1) Select "1. AE MODE" with 1-key.
2) Press [START] key.
3) Select the number corresponding to the operation specifica-
tions with 10-key.
4) Press [START] key.
When [START] key is pressed, the adjustment value is set.
(Operation setting in the auto copy mode)
1) Select the number corresponding to the mode with 10-key.
(Select one of 2 - 4.)
2) Press [START] key.
3) Select the number corresponding to the operation mode with
10-key.
1.PRINT START
2.EXP LEVEL
4.OC_CHARA
5.OC_MIX
8.SPF1_CHARA
64
9.SPF1_MIX
12.SPF2_CHARA
64
13.SPF2_MIX
16.CIS_CHARA
64
17.CIS_MIX
Press [SYSTEM SETTINGS] key.
Press [SYSTEM SETTINGS] key,
or terminate copying.
Press [START] key, or
press [SYSTEM SETTINGS] key.
Press [START] key, or
press [SYSTEM SETTINGS] key.
5.2.0
8.5.0
11.2.0(H)
14.5.0(H)
Density
MX-M350/M450 N/U SIMULATION 9 - 45
4) Press [START] key.
1
AE MODE
2
AE STOP MODE (COPIER)
1
64
3
AE STOP MODE (SCANNER)
4
AE STOP MODE (FAX)
64
Set
64
Mode
value
AE
1
64
mode
2
AE
0
64
fixed
1
mode
AE fixed OFF: The automatic density (exposure) control is per-
formed in real time. (The density level is changed
in real time according to the document pattern.)
AE fixed ON: The density at the lead edge of the document is
scanned, and the overall density (exposure) level is
determined according to the scanned density level.
(Overall density level fixed)
SIMULATION 46-19
EXP.MODE SETUP. SELECT 1-4, AND PRESS START.
1.AE MODE
2.AE STOP MODE(COPIER)
1
3.AE STOP
4.AE STOP MODE(FAX)
Select 1, and
press [START] key.
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 1-2, AND PRESS START.
1.AE MODE
1
Select 2, 3, or 4 and
press [START] key.
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 0-1, AND PRESS START.
2.AE STOP MODE(COPIER)
AE mode
AE fixed mode (Copier)
AE fixed mode (Scanner)
AE fixed mode (FAX)
Item
Image quality priority mode
(Normal mode)
∗ Gamma is sharp to provide
high contrast images.
Toner consumption priority mode
∗ Gamma is mild to provide low
contrast images.
AE fixed OFF
AE fixed ON
2
1
MODE(SCANNER)0
0
Press [SYSTEM SETTINGS] key.
Press [START] key, or
press [SYSTEM SETTINGS] key.
Default
2
1 (COPIER)
0
(SCANNER/
FAX)
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450 uM450 n

Table of Contents