Purpose
Adjustment/Operation test/Check
Function
Used to check and adjust the operation of the
(Purpose)
main charger grid voltage in each printer mode
and the control circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The main charger grid output voltage adjustment and output
check can be made in each print mode.)
Item
1 AUTO
Auto mode
2 CHARACTER Text mode
3 MIX
Text/Photo mode
4 PHOTO
Photo mode
5 PRINTER
Printer mode
6 FAX
FAX mode
SIMULATION 8-2
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO
645
2.CHARACTER
3.MIX
645
4.PHOTO
645
5.PRINTER
645
6.FAX
645
Press [START] key.
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-900)
Press [START] key.
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
8-6
Purpose
Adjustment/Operation test/Check
Function
Used to check and adjust the operation of the
(Purpose)
transfer voltage and the control circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)/Transfer
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
Default
Set
MX-
MX-
range
M350
M450
200 - 900 615
645
645
645
645
1
Press [SYSTEM SETTINGS] key.
645
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
645
MX-M350/M450 N/U SIMULATION 9 - 15
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in each print mode.)
Item
1 FRONT
Long side print mode
2 BACK
Back side print mode
SIMULATION 8-6
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT
267
2.BACK
310
Press [START] key.
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-620)
Press [START] key.
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
8-17
Purpose
Operation test/Check
Function
Used to check and adjust the operation of the
(Purpose)
transfer voltage and the related circuit. (Transfer
belt cleaning mode)
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Operation
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in the transfer belt cleaning mode.)
Item
1 SHF FRONT
AC component
2 SHV BACK
AC component
3 THV-
DC component
Default
Set
MX-
MX-
range
M350
M450
0 - 620
220
267
267
310
1
Press [SYSTEM SETTINGS] key.
267
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
267
Default
Set
MX-
MX-
range
M350
M450
0 - 240
120
160
0 - 240
120
160
0 - 1250
780
780