Sharp UX-8 Service Manual page 29

Table of Contents

Advertisement

SW-G4 No. 1 ~ No. 6 Quiet detect level setting
(0~-44dBm setting by 1dBm step)
This is used to change the quiet detect level setting.
If quiet detection is difficult due to noise, reduce this setting level.
(Example)
Factory setting : 1 0 1 1 0 0 (- 44dBm)
1 0 1 0 0 0 (- 40dBm)
SW-G4 No. 7 Fax switching when A.M. full
If the answering machine's memory (tape) is full and there is no response,
the machine automatically switches to Fax reception.
SW-G4 No. 8 Reserved
Set to "0".
SW-H1 No. 1 Busy tone continuous sound detect time
Set detecting time busy tone continuous sound for 5 seconds or 10 sec-
onds.
SW-H1 No. 2 Reserved
Set to "0".
SW-H1 No. 3 Busy tone detect continuation sound detect
Used to select detection of the continuous sound of certain frequency.
SW-H1 No. 4 Reserved
Set to "0".
SW-H1 No. 5 Busy tone detect intermittent sound detect
Used to select detection of the intermittent sound of certain frequency.
SW-H1 No. 6, No. 7 Busy tone detection pulse number
Used to set detection of Busy tone intermittent sounds.
SW-H1 No. 8 Reserved
Set to "0".
SW-H2 No. 1, No. 2 Busy tone detection ON/OFF time (Lower limit)
The initial value of detection is set according to electric condition.
The set value is changed according to the local switch board. (Errone-
ous detection of sound is reduced.)
If erroneous detection is caused by sound, etc., adjust the detection
range.
The lower limit can be set in the range of 150msec to 350msec.
SW-H2 No. 3, No. 4 Busy tone detection ON/OFF time (Upper limit)
Similarly to SW-H2 No. 1, No. 2, the set value can be varied.
The upper limit can be set in the range of 650msec to 2700msec.
SW-H2 No. 5 ~ No. 8 Reserved
Set to "0".
SW-I1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I4 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I5 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I6 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I7 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I8 No. 1 ~ No. 8 Reserved
Set to "0".
SW-J1 No. 1 Sender's phone number setting
Used to make a choice of whether the registered sender's phone number
can be changed or not. If the switch is set to "1", new registration of the
sender's phone number is disabled to prevent accidental wrong input.
SW-J1 No. 2 Reserved
Set to "0".
SW-J1 No. 3, No. 4 Ringer Volume
Used to adjust ringing volume.
SW-J1 No. 5, No. 6 Speaker Volume
Used to adjust sound volume from a speaker.
SW-J1 No. 7 Polling key (UX-40/FO-50 only)
If this switch is set to 1, the last of Rapid key works as polling key.
SW-J1 No. 8 Reserved
Set to "0".
SW-J2 No. 1 ~ No. 6 Reserved
Set to "0".
SW-J2 No. 7 Saving energy start timing
Used to set the time between the machine's stand-by state (clock indica-
tion) after operation and saving energy mode.
It is possible to set the time to either 5 sec or 180 sec (default).
SW-J2 No. 8 Saving energy mode
Used to select whether to make the saving energy mode valid or not.
SW-J3 No. 1 ~ No. 3 Communication results printout
(Transaction report)
It is possible to obtain transaction results after each communication.
Normally,the switch is set (No. 1 : 0, No. 2 : 0, No. 3 : 0) so that the
transaction report is produced only when a communication error is en-
countered.
If No.1 was set to 0 and No. 2 to 1 and No. 3 to 0, the transaction report
will be produced every time a communicaion is done, even if the
communicaion was successful.
Setting No. 1 to 0 and No. 2 to 1 and No. 3 to 1 will disable this function.
No transaction report printed.
SW-J3 No. 4 Time format
When set to "0", 24hour time format is used.
When set to "1", 12hour time format is used.
SW-J3 No. 5 Date format
When set to "0", Day-Month-Year format is used.
When set to "1", Month-Day-Year format is used.
SW-J3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering diag mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED key
is pressed, the switch is changed from the stand-by state to the diag
mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".
2 – 17
UX-8TH/UX-40TH
GQ-5TH/FO-50TH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gq-5Fo-50Ux-40

Table of Contents