York PT8-UH Technical Manual

York PT8-UH Technical Manual

Gas-fired high efficiency two stage upflow/horizontal furnaces standard & low nox 80% afue
Hide thumbs Also See for PT8-UH:

Advertisement

TECHNICAL GUIDE
AFFINITY
MODELS: PT8-UH
GAS-FIRED
HIGH EFFICIENCY TWO STAGE
UPFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx
80% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
• Integrated control module for reliable, economical opera-
• Electronic Hot Surface Ignition saves fuel cost with
• Induced combustion system with inshot main burners for
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
• 24V, 40 VA control transformer and blower relay supplied
• Hi-tech tubular aluminized steel primary heat exchanger.
• Timed on, adjustable off blower capability for maximum
ISO 9001
• Solid removable bottom panel allows easy application.
Certified Quality
Management System
• Easy access from front of unit for cleaning, maintenance
• Insulated blower compartment for quiet operation.
• Independent door removal for greater durability and ease
• Low NOx models have been designed to meet specific
• Low NOx models may not be converted to propane unless
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Two speed blower operation
Provides increased comfort level & very quiet unit oper-
ation
Adjustable delay timer allows two stage operation with
single stage thermostat
tion.
tion.
increased dependability and reliability.
quiet, efficient operation.
blower.
for add-on cooling.
comfort.
or service.
of access.
code requirements.
screens are removed.
246755-YTG-D-0407

Advertisement

Table of Contents
loading

Summary of Contents for York PT8-UH

  • Page 1 • Insulated blower compartment for quiet operation. specifications are subject to change without notice. • Independent door removal for greater durability and ease Visit us on the web at www.york.com for the most of access. up-to-date technical information. • Low NOx models have been designed to meet specific code requirements.
  • Page 2: Cabinet And Duct Dimensions

    246755-YTG-D-0407 4” Diameter (VENT CONNECTIONS) POWER WIRING 7/8” HOLE 14-3/4 13-3/4 5-3/8 2-1/2 32-1/2 GAS INLET ACCESS 1-1/4 x 2-1/2 WIRING 7/8” K.O. T’STAT WIRING 7/8” K.O. 23-1/2 2-1/4 8-3/4 1-1/8 30-1/8 LEFT SIDE RIGHT SIDE FRONT 1-1/2 1-1/4 26-3/4 4”...
  • Page 3 246755-YTG-D-0407 BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - BOTTOM RETURN Bottom Airflow Data (SCFM) Models Speed Ext. Static Pressure (in. H2O) High 1610 1540 1460 1360 1290 1200 1110 1020 Medium High 1430 1390 1330 1250 1190 1110 1030 PT8A12N040UH11 Medium Low 1200...
  • Page 4 246755-YTG-D-0407 BLOWER PERFORMANCE CFM - UPFLOW (WITHOUT FILTER) - LEFT SIDE RETURN Left Side Airflow Data (SCFM) Models Speed Ext. Static Pressure (in. H2O) High 1810 1730 1660 1570 1480 1390 1300 1200 1090 Medium High 1390 1390 1350 1320 1270 1210 1150...
  • Page 5: Horizontal Sidewall Venting

    246755-YTG-D-0407 HORIZONTAL SIDEWALL VENTING NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown below are typical values for the type of For applications where vertical venting is not possible, the filter listed and should only be used as a guideline. Actual only approved method of horizontal venting is the use of an pressure drop ratings for each filter type vary between filter auxiliary power vent.
  • Page 6: Applying Filter Pressure Drop To Determine System Airflow

    246755-YTG-D-0407 APPLYING FILTER PRESSURE DROP TO ACCESSORIES DETERMINE SYSTEM AIRFLOW PROPANE (LP) CONVERSION KIT - To determine the approximate airflow of the unit with a filter in 1NP0347 - All units place, follow the steps below: This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation.
  • Page 7 246755-YTG-D-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart - AC Unitary Products Group...
  • Page 8 Thermostat Chart - HP Subject to change without notice. Printed in U.S.A. 246755-YTG-D-0407 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 246755-YTG-C-0806 Unitary 5005 Norman Products York Group Drive 73069...

This manual is also suitable for:

Pt8a12n040uh11Pt8a12n060uh11Pt8a12l060uh11Pt8a12n080uh11Pt8a12l080uh11Pt8b16n080uh11 ... Show all

Table of Contents