INSTALLATION INSTRUCTION
MODELS: P2MP (U.S.) - STYLE G
(Upflow/Horizontal)
32-112 MBH OUTPUT
UPFLOW
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Open windows.
Do not touch any electrical switch;
do not use any phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
®
MULTI-POSITION GAS-FIRED FURNACES
Supersedes: 650.69-N3Y (1294)
DIAMOND SERIES FURNACES
P9MP (Canada) - STYLE E
HORIZONTAL (RIGHT)
HORIZONTAL (LEFT)
INDUCED-DRAFT STYLE G
MODELS P2DP -
STYLES C, D
(Downflow)
48-104 MBH OUTPUT
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COM-
PLIANCE WITH THE ENCLOSED INSTALLATION IN-
STRUCTIONS AND ANY APPLICABLE LOCAL, STATE, AND
NATIONAL CODES INCLUDING BUT NOT LIMITED TO,
B U I L D I N G , E L E C T R I C A L A N D M E C H A N I C A L
CODES.
WARNING
IMPROPER INSTALLATION MAY CREATE A CONDITION
WHERE THE OPERATION OF THE PRODUCT COULD
CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance
.
WARNING: Improper installation, adjustment, al-
teration, service or maintenance can cause injury
or property damage. Refer to this manual. For as-
sistance or additional information, consult a quali-
fied installer, service agency or the gas supplier.
650.69-N3Y (1095)
035-13581
DOWNFLOW

Advertisement

Table of Contents
loading

Summary of Contents for York P2MP Series

  • Page 1 ® MULTI-POSITION GAS-FIRED FURNACES INDUCED-DRAFT STYLE G INSTALLATION INSTRUCTION Supersedes: 650.69-N3Y (1294) 650.69-N3Y (1095) DIAMOND SERIES FURNACES 035-13581 MODELS P2DP - MODELS: P2MP (U.S.) - STYLE G STYLES C, D P9MP (Canada) - STYLE E (Downflow) (Upflow/Horizontal) 48-104 MBH OUTPUT 32-112 MBH OUTPUT HORIZONTAL (RIGHT) UPFLOW...
  • Page 2: Table Of Contents

    650.69-N3 A separate request for inspection by the carrier’s agent should be TABLE OF CONTENTS made in writing. Also, before installation, the unit should be checked for screws or bolts which may have loosened in transit. GENERAL INFORMATION Description ..............2 NOTES, CAUTIONS &...
  • Page 3: Clearances

    650.69-N3 The size of the unit should be based on an acceptable heat loss UNIT INSTALLATION calculation for the structure. ACCA, Manual J or other approved COMBUSTION AIR methods may be used. The furnace should be located using these guidelines: All installations must comply with Section 5.3, Air for Combus- tion and Ventilation of the National Fuel Gas Code, ANSI 1.
  • Page 4: Dimensions

    650.69-N3 13-3/4 14-3/4 5-3/4 2-1/2 32-1/2 2-1/4 23-1/2 8-3/4 1-1/8 28-1/2 Model 12-1/4 P MPD08 03201 1-1/8 16-1/4 P MPD08 04801 16-1/4 P2MPD12 04801 26-3/4 16-1/4 P MPD12 06401 22-1/4 P2MPD16 06401 22-1/4 P MPD14 08001 22-1/4 P2MPD20 08001 Vent Connection 1-1/8 22-1/4 P2MPD16...
  • Page 5 650.69-N3 7-1/8 5-3/4 2-1/2 28-1/2 FRONT LEFT SIDE RIGHT SIDE 1-1/8 All dimensions are in inches and are approximate. Model 16-1/4 P2DPD10 04801 1-1/8 16-1/4 P2DPD12 06401 22-1/4 P2DPD12 08001 F R O N T FRONT V e nt C o n n e c t io n ( ve n t s iz e ) 22-1/4 P2DPD16...
  • Page 6: Venting

    650.69-N3 ANSI Z223.1 or CAN/CGA B149.1 or .2 Installation Code The recommended source of combustion air is to use the outdoor air supply. Excessive exposure to contaminated com- - latest editions. bustion air will result in safety and performance related prob- The following steps shall be followed with each appliance lems.
  • Page 7: Filters (Upflow/Horizontal)

    650.69-N3 UPFLOW APPLICATION Supply Plenum Connection Attach the supply plenum to the furnace outlet duct connection flanges. This is typically through the use of "S" cleat material when a metal plenum is used. The use of an approved flexible duct connector is recommended on all instal- lations.
  • Page 8: Horizontal Application

    650.69-N3 2. Remove the four screws securing the front bottom angle and support the weight of the furnace. Seal the furnace to the remove it from the unit. Keep the angle for reinstallation. plenum to prevent air leakage. 3. Remove the screws from the furnace wrapper which secure NOTE: If an external mounted filter rack is being used, see the the bottom closure panel and remove the panel from the instructions provided with that accessory for proper hole...
  • Page 9: Downflfow Application

    650.69-N3 DOWNFLOW APPLICATION DOWNFLOW FILTERS A top return filter rack is supplied with the furnace. Two 14" x 20" permanent washable filters are supplied with each unit. Refer to Downflow Application for details. Downflow furnaces typically are installed with the filters located above the furnace, extending into the return air duct.
  • Page 10 650.69-N3 The furnace must be isolated from the gas supply piping system by closing its individual external manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.48 kPa). CAUTION: Never apply a pipe wrench to the body of the combination automatic gas valve.
  • Page 11: Electrical Connections

    650.69-N3 NOTE: The furnace’s control system depends on correct po- CAUTION: Main power supply to the unit must still be inter- rupted at the main power disconnect switch before any larity of the power supply. service or repair work is to be done to the unit. Do not rely Connect the power supply as shown on the unit wiring label on upon the interlock switch as a main power disconnect.
  • Page 12: Adjustment Of Manifold Gas Pressure

    650.69-N3 TABLE 4 - GAS RATE (Cubic Feet Per Hour) Seconds for Size of Test Dial One Revolution 1/2 cubic foot 1 cubic foot FIGURE 14 - GAS VALVES TOP - WHITE-RODGERS 36E97 BOTTOM - HONEYWELL VR8205 If the actual input is not within ± 2% of the furnace rating, with 4.
  • Page 13: Adjustment Of Temperature Rise

    650.69-N3 WARNING: If manifold pressure is too high, an over-fire con- CAUTION: Do not energize more than one motor speed at a dition exists which could cause heat exchanger failure. If time or damage will result. the manifold pressure is too low, sooting and eventual clogging of the heat exchanger could occur.
  • Page 14: Operation & Maintenance

    650.69-N3 If flame is established for more than 10 seconds after ignition, OPERATION AND MAINTENANCE the control will clear the ignition attempt (retry) counter. If flame SEQUENCE OF OPERATION is lost after 10 seconds, it will restart the ignition sequence. This can occur a maximum of five times.
  • Page 15: Heat Exchangers

    650.69-N3 9. Reinstall the blower assembly. Replace mounting screws 2. The manual shutoff valves in the gas line to the furnace that hold the blower assembly to the front portion of the must be open. blower deck. Two mounting screws used on the sides of the blower are used for shipping purposes only, and are 3.
  • Page 16: Troubleshooting Charts

    650.69-N3 Unitary Products Group...
  • Page 17 650.69-N3 Unitary Products Group...
  • Page 18 650.69-N3 Unitary Products Group...
  • Page 19: Unit Wiring Diagrams

    650.69-N3 WIRING DIAGRAM - UPFLOW MULTI-SPEED MODELS NOTE: The furnace’s control system depends on correct polarity of the power supply. Unitary Products Group...
  • Page 20 650.69-N3 WIRING DIAGRAM - DOWNFLOW MODELS NOTE: The furnace’s control system depends on correct polarity of the power supply. Unitary Products Group...
  • Page 21: Blower Performance

    650.69-N3 BLOWER PERFORMANCE - UPFLOW/HORIZONTAL - CFM (Includes Filter) SPEED EXTERNAL STATIC PRESSURE, INCHES W.C. MODEL 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 HIGH 1150 1090 1021 — — P2MPD08N03201 1027 — — (See Note 1) — —...
  • Page 22 650.69-N3 BLOWER PERFORMANCE - DOWNFLOW - CFM (Includes Filter) EXTERNAL STATIC PRESSURE, INCHES W.C. SPEED MODEL 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 HIGH 1356 1315 1222 1154 1090 1144 1080 1023 P2DPD10 04801 HIGH 1557 1502 1410 1344 1240...
  • Page 23 650.69-N3 NOTES Unitary Products Group...
  • Page 24 650.69-N3Y (1294) Unitary Products Group P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Code: SBY Copyright © by York International Corporation 1994. All Rights Reserved.

This manual is also suitable for:

P9mp seriesP2dp series