OBJ_BUCH-1054-001.book Page 7 Friday, July 17, 2009 1:30 PM
Products sold in GB only: Your product is fitted
with an BS 1363/A approved electric plug with
internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets,
it should be cut off and an appropriate plug fitted
in its place by an authorised customer service
agent. The replacement plug should have the
same fuse rating as the original plug.
The severed plug must be disposed of to avoid a
possible shock hazard and should never be in-
serted into a mains socket elsewhere.
Products sold in AUS and NZ only: Use a residu-
al current device (RCD) with a rated residual cur-
rent of 30 mA or less.

Functional Description

Read all safety warnings and all in-
structions. Failure to follow the
warnings and instructions may result
in electric shock, fire and/or serious
injury.
While reading the operating instructions, unfold
the graphics page for the machine and leave it
open.

Intended Use

The machine is intended for vacuuming and
blowing of materials that are not hazardous to
one's health.
The machine is not suitable for vacuuming and
blowing of flammable materials, metal chips and
sharp objects, such as screws or nails.
Bosch Power Tools

Product Features

The numbering of the product features refers to
the illustration of the machine on the graphics
page.
1 Handle
2 On/Off switch
3 Lock-on button for On/Off switch
4 Thumbwheel for regulation of the air volume
5 Air outlet
6 Caps for carbon brushes
7 Nozzle
8 Dust bag
9 Air intake
10 Carbon brushes
*Accessories shown or described are not part of the
standard delivery scope of the product. A complete
overview of accessories can be found in our acces-
sories program.

Technical Data

Blower/Vac
Article number
Rated power input
Air volume
Air pressure
Weight according to
EPTA-Procedure
01/2003
Protection class
The values given are valid for nominal voltages [U] of
230/240 V. For lower voltage and models for specific
countries, these values can vary.
Please observe the article number on the type plate of
your machine. The trade names of the individual ma-
chines may vary.
English | 7
GBL 800 E
Professional
3 601 J80 4..
W
820
3
m
/min
4.5
mbar
0–72
kg
1.8
/ II
1 609 929 R63 | (17.7.09)