Water Supply Requirements

60 psi (413.7 kilopascals) (4.1 bar) maximum static pressure. 30 psi (206.8 kilopascals) (2.1 bar) minimum dynamic
pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 (88.7 ml) per second water flow. Optimum
recommended pressure 50 psi (344.7 kilopascals) (3.5 bar) dynamic pressure.

Ice Bank/Pull Down

Weight 14-16 lbs. Pull Down: 3.5 - 5 hours at 75°F (24°C)
R
ECEIVING
Each unit is completely tested and inspected before shipment. At the time of shipment, the carrier accepts the
unit and any claim for damage must be made with the carrier.
Upon receiving the unit(s) from the carrier, inspect the carton for visible damage. If damage exists, have the
carrier make a note on the bill of lading and file a claim with the carrier.
U
NPACKING
Remove staples securing carton to pallet.
Lift carton up and off of unit.
Remove inserts and shipping bag.
Open upper cabinet door and remove installation kit.
Remove bolts securing unit to pallet.
Lift unit off of pallet.
NOTE: Do not lay the unit on it's side or back. This may cause vital oils to drain from the compressor
resulting in damage during start-up and consequently voiding the warranty.
C
L
OUNTER
OCATION
Select a location in a well ventilated area, close to a grounded electrical outlet. If possible do not place the unit
close to hot and/or steaming machines.
The minimum airflow clearance is: 4" (10.16 cm) in back and 12" (30.48 cm) on top and open to the front.
IMPORTANT:
Condenser air is drawn in from the bottom of the rear panel and discharged out the top of the
rear panel. Failure to maintain clearance space will reduce capacity of the unit and cause
premature compressor failure.
Typically the dispenser is placed directly on the counter and a food grade silicone sealant applied around the
base. However, supplied with the dispenser is a counter top sealing gasket. This eliminates the need for sealant
and is much easier to use.
Publication Number: 720901117INS
MINIMUM 12"
AIR FLOW CLEARANCE
Figure 2. Minimum Clearances
- 4 -
AIR FLOW CLEARANCE
MINIMUM 4"
© 2003-2010, IMI Cornelius Inc.