REQUIREMENTS
Figure 1. Unit Dimensions

Nameplate Data

Model QST 4000, 115 VAC, 4.5 amps, 1 phase 60 hertz, 6.75 oz. (191-193g) R-134a refrigerant. Test press: High
side 400 psi (27.6 bar). Low side 100 psi (6.9 bar).
Model QST 4000,230 VAC, 3 amps, 1 phase 60hertz, 6.75 oz. (191-193g) R-134a refrigerant. Test press: High side
400 psi (27.6 bar. Low side 100 psi (6.9 bar).

Concentrate Storage

Four 0.8 gallon (3.0 liter) disposable bottles.

Recommended Clearance

12" (30.48 cm) on top and 4" (10.16 cm) required in back for air circulation.

Electrical Connection

6 ft. long (1.83 m) power cord with 3-prong plug attached to dispenser. Export models have a line cord less plug.
!
CAUTION:
ONLY trained and certified electrical technicians should replace the power cord or the unit should be returned to
an Authorized Service Center for power cord replacement." The replacement cord must meet all requirements of
the original equipment manufacturer.
Failure to comply could result in serious injury, death or damage to the equipment.

Power Supply

15 amps at 120 volts dedicated power supply.
20 amps at 230 volts dedicated power supply.

Water Connection

3/8 in. (0.95 cm) SAE male flare fitting on dispenser.
The new hose sets supplied with the appliance are to be used and that old hose sets should not be reused.