Note: The following Simpson Duravent kits are
recommended for use with this appliance.
High-Wind
(Broadway 46DVA-CL33)
(Brentwood 46DVA-CL34)
Prairie Co-Linear Kit
(Broadway 46DVA-CL33P)
(Brentwood 46DVA-CL34P)
Only certified venting systems or components may
be installed with this fireplace.
1) Measure chimney height, cut flex liner (min.10') as
required. Mark one pipe at both ends to identify
combustion air intake pipe from flue outlet pipe.
2) Attach marked flex liner pipe to the intake side of
vent terminal. Seal and secure with sealant and
screws provided. Attach the other pipe to the outlet
side of vent terminal. Seal and secure with sealant
and screws provided.
3) Insert both flex liners from top of the chimney, down
through the damper opening.
4) Before attaching vent terminal to top of chimney,
apply a bead of caulking to top of clay liner. Slip
vent terminal over liner and secure in place with
lateral retaining bolts.
5) For larger chimneys, an optional flashing is
available which may be cut and fitted to suit. The
flashing attaches to the underside of the terminal
with four nuts provided. Caulk the flashing in place
to seal any gaps.
Figure 21: Flue Adaptor Plate Conections

Venting

Figure 22: High Wind Vent Terminal
20
MAX. Vent Height
35' (10.7m)
26'-35'
Full Closed
16'-26'
1/2 Open
10'-16'
Full Open
Min. Vent Height
Figure 20: Venting
10' (3m)