Outside Installation - Rheem RKNA SERIES Installation Instructions Manual

Package gas electric 3-5 tons
Table of Contents

Advertisement

WARNING
!
THIS UNIT MAY BE USED TO HEAT
THE BUILDING OR STRUCTURE
DURING CONSTRUCTION IF THE
FOLLOWING INSTALLATION
REQUIREMENTS ARE MET.
INSTALLATION MUST COMPLY
WITH ALL INSTALLATION
INSTRUCTIONS INCLUDING:
• PROPER VENT INSTALLATION;
• FURNACE OPERATING UNDER
THERMOSTATIC CONTROL;
• RETURN AIR DUCT SEALED TO
THE FURNACE;
• AIR FILTERS IN PLACE;
• SET FURNACE INPUT RATE AND
TEMPERATURE RISE PER RAT-
ING PLATE MARKING;
• MEANS OF PROVIDING OUT-
DOOR AIR REQUIRED FOR COM-
BUSTION;
• RETURN AIR TEMPERATURE
MAINTAINED BETWEEN 55°F
(13°C) AND 80°F (27°C); AND
• INSTALLATION OF EXHAUST
AND COMBUSTION AIR INLET
HOODS COMPLETED;
• CLEAN FURNACE, DUCT WORK
AND COMPONENTS UPON SUB-
STANTIAL COMPLETION OF THE
CONSTRUCTION PROCESS, AND
VERIFY FURNACE OPERATING
CONDITIONS INCLUDING IGNI-
TION, INPUT RATE, TEMPERA-
TURE RISE AND VENTING,
ACCORDING TO THE INSTRUC-
TIONS.
FIGURE 5
OUTSIDE SLAB INSTALLATION. CLOSET DISTRIBUTION SYSTEM. SLAB FLOOR CONSTRUCTION.
B. OUTSIDE SLAB INSTALLATION
WARNING
!
THESE UNITS ARE DESIGNED CERTIFIED FOR OUTDOOR INSTALLATION
ONLY. INSTALLATION INSIDE ANY PART OF A STRUCTURE CAN RESULT IN
INADEQUATE UNIT PERFORMANCE AS WELL AS PROPERTY DAMAGE.
INSTALLATION INSIDE CAN ALSO CAUSE RECIRCULATION OF FLUE PROD-
UCTS INTO THE CONDITIONED SPACE RESULTING IN PERSONAL INJURY
(Typical outdoor slab installation is shown in Figure 5.)
1. Select a location where external water drainage cannot collect around unit.
2. Provide a level slab sufficiently high enough above grade to prevent surface water
from entering the unit
3. The location of the unit should be such as to provide proper access for inspection
and servicing as shown in Figure 7.
4. Locate unit where operating sounds will not disturb owner or neighbors.
5. Locate unit so roof runoff water does not pour directly on the unit. Provide gutter or
other shielding at roof level. Do not locate unit in an area where excessive snow
drifting may occur or accumulate.
6. Where snowfall is anticipated, the height of the unit above the ground level must be
considered. Mount unit high enough to be above anticipated maximum area snowfall
and to allow combustion air to enter the combustion air inlet.
7. Select an area which will keep the areas of the vent, air intake, and A/C condenser
fins free and clear of obstructions such as weeds, shrubs, vines, snow, etc. Inform
the user accordingly.
8. Remove compressor shipping supports (if so equipped) after installation.
I298
7