10.1.2. Refrigerant additional charge
• The piping length exceeds 30 metres.
APPLICABLE FOR ALL MODELS
Before shipment, this air conditioner is filled with the rated amount of refrigerant subject to 30m piping length. (The rated
amount of refrigerant is indicated on the name plate.) But when the piping length exceeds 30m, additional charge is required
according to the following table.
Example :
CS-F24DD2E5
In case of 31m long pipe (one-way), the amount of refrigerant to be replenished is: (31 - 30) x 50 = 50g

10.2. Position of the centre gravity

MODEL NAME
WIDTH (mm)
CU-B24DBE5
CU-B28DBE5
CU-B28DBE8
CU-B34DBE5
CU-B34DBE8
CU-B43DBE8
CU-B50DBE8
Model Name
Liquid piping
(dia. mm)
CU-B24DBE5
9.52
CU-B28DBE5
9.52
CU-B28DBE8
9.52
CU-B34DBE5
9.52
CU-B34DBE8
9.52
CU-B43DBE8
9.52
CU-B50DBE8
9.52
OUTSIDE DIMENSIONS
DEPTH (mm)
900
320
900
320
900
320
900
320
900
320
900
320
900
320
Standard piping specification
Gas piping
Gas charge-
(dia. mm)
less length (m)
15.88
30
15.88
30
15.88
30
15.88
30
15.88
30
15.88
30
15.88
30
NET WEIGHT
HEIGHT (mm)
kg
795
69
795
69
795
69
1170
102
1170
100
1170
102
1170
102
44
Additional gas
volume (g/m)
50
50
50
50
50
50
50
CENTRE OF GRAVITY
X (mm)
Y (mm)
560
150
560
150
560
150
560
150
560
150
560
150
560
150
Z (mm)
320
320
320
450
450
450
450