Safety Device - Panasonic CS-F24DD2E5 Service Manual

Panasonic air conditioner service manual
Hide thumbs Also See for CS-F24DD2E5:
Table of Contents

Advertisement

13.6. Safety device

13.6.1. Indoor unit
Indoor unit
For fan motor protection
Internal
protector
For control protection
Fuse
For fan motor protection
Fuse
13.6.2. Outdoor unit
Outdoor unit
Heat pump
model
For refrigerant cycle
High pressure
OFF
switch (63H1)
ON
For compressor
Over current
protection
Heat pump model
OFF
RESET
Discharge temp
protection
Discharge
Compressor
temperature
OFF
thermistor (Th1)
Liquid compress
protection
Crankcase heater
Input power
Compressor
protection
Internal protector
OFF
ON
trip time
For fan motor
protection
Internal
OFF
protector (49F)
ON
Heating control
(Heat pump only)
Pressure switch
OFF
(Fan speed) (63H2)
ON
Cooling control
Heat exchanger
outlet temp
Control method
thermistor (Th2)
For control
protection
Fuse
CUT
2
1MPa = 10.2kgf/cm
Heat pump model
CS-F24DD2E5
Cooling only model
OFF
°C
135
ON
°C
85
CUT
A
3.15
CUT
A
-
50Hz CU-B24DBE5 CU-B28DBE5 CU-B28DBE8 CU-B34DBE5 CU-B34DBE8 CU-B43DBE8 CU-B50DBE8
MPa
4.15
4.15
MPa
3.05
3.05
A
19
20
-
Automatic
Automatic
°C
115
115
W
37
37
°C
160
165
50Hz
°C
90
90
50Hz
50Hz
3-10sec/65A 3-10sec/78A 3-10sec/25A
°C
135
135
°C
85
85
MPa
-
MPa
-
A
6.3
6.3
CS-F28DD2E5
135
135
135
85
85
85
3.15
3.15
3.15
-
-
-
4.15
4.15
3.05
3.05
7.5
29
Automatic
Automatic
115
120
37
37
165
160
80
90
135
135
85
86
-
-
-
-
40°C → High speed
Th
Th < 40°C → 5 speed step control
6.3
6.3
133
CS-F34DD2E5
CS-F43DD2E5 CS-F50DD2E5
135
135
135
85
85
85
3.15
3.15
3.15
-
-
-
4.15
4.15
3.05
3.05
11
14
Automatic
Automatic
120
120
37
37
160
160
90
90
-
-
135
135
86
86
-
-
-
-
6.3
6.3
135
85
3.15
-
4.15
3.05
15
Automatic
120
37
160
90
-
-
135
86
-
-
-
-
6.3